cxa1597m Sony Electronics, cxa1597m Datasheet - Page 6

no-image

cxa1597m

Manufacturer Part Number
cxa1597m
Description
Recording Equalizer Amplifier For Stereo Cassette Decks
Manufacturer
Sony Electronics
Datasheet
METAL-NORM mode
REC-EQ frequency response 3
(12kHz, –20dB)
NORM-HIGH mode
REC-EQ frequency response 1
(5kHz, –20dB)
NORM-HIGH mode
REC-EQ frequency response 2
(15kHz, –20dB)
NORM-HIGH mode
REC-EQ frequency response 3
(20kHz, –20dB)
CrO
REC-EQ frequency response 1
(5kHz, –20dB)
CrO
REC-EQ frequency response 2
(15kHz, –20dB)
CrO
REC-EQ frequency response 3
(20kHz, –20dB)
METAL-HIGH mode
REC-EQ frequency response 1
(5kHz, –20dB)
METAL-HIGH mode
REC-EQ frequency response 2
(15kHz, –20dB)
METAL-HIGH mode
REC-EQ frequency response 3
(20kHz, –20dB)
NORM-NORM mode
REC-EQ signal handling
NORM-NORM mode
REC-EQ total harmonic distortion
(1kHz, 0.0dB, RL = 2.7k )
2
2
2
-HIGH mode
-HIGH mode
-HIGH mode
Item
METAL-tape, NORM-speed mode
Input a 12kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
NORM-tape, HIGH-speed mode
Input a 5kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
NORM-tape, HIGH-speed mode
Input a 15kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
NORM-tape, HIGH-speed mode
Input a 20kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
CrO
Input a 5kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
CrO
Input a 15kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
CrO
Input a 20kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
METAL-tape, HIGH-speed mode
Input a 5kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
METAL-tape, HIGH-speed mode
Input a 15kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
METAL-tape, HIGH-speed mode
Input a 20kHz signal (–20dB level down) to the
REC IN pins and then measure the relative
deviation from NORM-NS, 315Hz mode.
NORM-tape, NORM-speed mode, RL = 2.7k
Input a 1kHz signal and set the output so that
THD (total harmonic distortion) is 1%. (Measure
the distortion of a +11dB level-up signal.)
NORM-tape, NORM-speed mode, RL = 2.7k
Input a 1kHz, 0.0dB (reference input level)
signal and measure the distortion. (Measure the
distortion as THD + N.)
2
2
2
-tape, HIGH-speed mode
-tape, HIGH-speed mode
-tape, HIGH-speed mode
– 6 –
Conditions
10.4
–1.3
11.4
11.8
11.0
Min.
4.0
7.4
3.9
8.6
5.9
9.5
Typ.
13.4
10.9
11.1
14.9
12.0
15.3
12.0
0.14
0.2
6.5
5.4
7.4
Max. Unit
CXA1597M/P
16.4
14.4
13.6
18.4
14.5
18.8
1.7
9.0
6.9
8.9
0.6
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
%