SI3232 SILABS [Silicon Laboratories], SI3232 Datasheet - Page 76

no-image

SI3232

Manufacturer Part Number
SI3232
Description
DUAL PROGRAMMABLE CMOS SLIC WITH LINE MONITORING
Manufacturer
SILABS [Silicon Laboratories]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3232-BQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
SI3232-FQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
SI3232-G-FQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
SI3232-G-FQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
SI3232-G-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
SI3232-GQ
Manufacturer:
ST
Quantity:
1
Part Number:
SI3232-GQ
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si3232
LINEFEED: Linefeed Control (Register Address 6)
(Register type: Operational)
Reset settings = 0x00
76
Name
Type
Bit
6:4
2:0
Bit
7
3
Reserved
Reserved
LFS[2:0]
LF[2:0]
Name
D7
D6
Read returns zero.
Linefeed Shadow.
This register reflects the actual realtime linefeed status. Automatic operations may cause
actual linefeed state transitions regardless of the Linefeed register settings (e.g., when
the Linefeed register is in the ringing state, the Linefeed Shadow register will reflect the
ringing state during ringing bursts and the OHT state during silent periods between ring-
ing bursts).
000 = Open
001 = Forward Active
010 = Forward On-hook Transmission (OHT)
011 = TIP Open
100 = Ringing
101 = Reverse Active
110 = Reverse On-hook Transmission
111 = RING Open
Read returns zero.
Linefeed.
Writing to this register sets the linefeed state.
000 = Open
001 = Forward Active
010 = Forward On-hook Transmission (OHT)
011 = TIP Open
100 = Ringing
101 = Reverse Active
110 = Reverse On-hook Transmission
111 = RING Open
LFS[2:0]
D5
R
Preliminary Rev. 0.96
D4
D3
Function
D2
LF[2:0]
R/W
D1
D0