ced3-750 Fuji Electric holdings CO.,Ltd, ced3-750 Datasheet

no-image

ced3-750

Manufacturer Part Number
ced3-750
Description
Instrument Transformers Zct, Evt And Special Purpose Ct
Manufacturer
Fuji Electric holdings CO.,Ltd
Datasheet
H.V. Distribution Equipment
Instrument transformers
ZCT, EVT and special purpose CT
I
FUJI can supply special purpose CTs,
ZCTs (Zero-phase current
transformers) and EVTs (Earthing
voltage transformers) as well as
standard FUJI instrument transformers.
Some of the versions are described
below.
CED and ZCED
The CED and ZCED are split-
construction types.They can be
mounted in position without
disconnecting the cables.
CED: Epoxy-molded split-toroidal type CT
ZCED: Epoxy-molded split-toroidal type
ZCE
ZCE type is toroidal-type ZCTs and
molded in epoxy resin.
GVE and GPE
GVE and GPE series are 3-phase
earthing voltage transformers.
GVE: Epoxy-molded type (3.3kV,
6.6kV)
GPE: Epoxy-molded type (11 to 33kV)
Note: All types are for indoor use only.
I Toroidal type ZCT
11/46
Description
Indoor use
Epoxy molded
toroidal type
Indoor use
Epoxy molded
split-toroidal
type
Description
ZCT
Hole
diameter
(mm)
65
80
100
125
190
65
90
100
130
150
Primary
current
(A)
0–200
0–400
0–750
0–1200
0–3000
0–200
0–400
0–600
0–750
0–1500
I
• Toroidal type ZCT
Basic type
ZCE: Epoxy molded toroidal type
ZCED: Epoxy molded
Hole diameter, mm
1: 65
2: 80 (ZCE type)
3: 100
Rated primary current (Amps.): 200 to 1500
• Split-toroidal type CT
Basic type
Hole diameter, mm
1: 65
2: 90
3, 3A, 3B: 100
4: 130
Rated primary current (Amps)
200 to 3000
Toroidal type ZCT
Rated zero-phase
current (mA) burden
Primary
200
200
Type number nomenclature
90 (ZCED type)
split-toroidal type
ZCE2A
Secondary
1.5
1.5
4: 125 (ZCE type)
5: 190 (ZCE type)
150 (ZCED type)
130 (ZCED type)
Split-toroidal
type CT
CED2
CP-622
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
ZCE
CP-620
CED
Rated
constant
(Ω)
10
10
A/
/
• Earthing voltage transformer EVT
Basic type
GVE, GPE: Epoxy-molded type
Secondary rated burden
GVE
1: 3 x 100VA
2: 3 x 200VA
Rated primary voltage
3: 3.3kV
6: 6.6kV
Rated secondary voltage
Overcurrent
(n
n
n
0
0
Information subject to change without notice
0
> 2000
> 2000
)
10: 11kV
15: 13.2kV
21: 3 x 200VA
13: 3 x 200VA
12: 3 x 200VA
9: 3 x 200VA
8: 3 x 200VA
7: 3 x 200VA(400A)
GPE:
Type
ZCE1A/200
ZCE2A/400
ZCE3A/750
ZCE4A/1200
ZCE5A/3000
ZCED1/200
ZCED2/400
ZCED3/600
ZCED4/750
ZCED5/1500
(
Earthing voltage
transformer
GVE1
20: 22kV
30: 33kV
) Available on request
GPE
-
CP-619
F -

Related parts for ced3-750

ced3-750 Summary of contents

Page 1

... Rated primary voltage 3: 3.3kV 10: 11kV 20: 22kV 6: 6.6kV 15: 13.2kV 30: 33kV Rated secondary voltage ( ) Available on request Overcurrent Type ( > 2000 ZCE1A/200 0 ZCE2A/400 ZCE3A/750 ZCE4A/1200 ZCE5A/3000 n > 2000 ZCED1/200 0 ZCED2/400 ZCED3/600 ZCED4/750 ZCED5/1500 Information subject to change without notice ...

Page 2

... Type CED1/200 CED1/300 CED1/400 CED1/500 CED1/600 CED1/750 CED2/200 CED2/300 CED2/400 CED2/500 CED2/600 CED2/750 CED2/1000 CED2/1200 CED2/1500 CED3/300 CED3/400 CED3/500 CED3/600 CED3/750 CED3/1000 CED3/1200 CED3/1500 CED3/2000 CED3/3000 CED3A/300 CED3A/400 CED3A/500 CED3A/600 CED3B/300 CED4/400 CED4/500 CED4/600 CED4/750 CED4/800 CED4/1000 CED4/1200 CED4/1500 CED4/2000 CED4/3000 11/47 11 ...

Page 3

H.V. Distribution Equipment Instrument transformers I Earthing voltage transformer EVT Rated voltage (V) Rated burden (VA) Primary Secondary Tertiary Secondary 3 × 100 3300 110 110 3 × 200 3 3 × 100 6600 110 110 3 × 200 3 ...

Page 4

... Y Z CED1 95 260 225 CED2 110 310 285 CED3 110 340 295 CED3A 200 340 295 L CED3B 250 340 295 CED4 125 350 305 Dimensions for reference only. Please confirm before construction begins. (V) ( ...

Page 5

H.V. Distribution Equipment Instrument transformers I Dimensions Earthing voltage transformer VT (with fuse links) GPE9- Earth terminal M8 ø Name plate 295 452 226 226 135 160 u ...

Related keywords