f75373 Feature Integration Technology Inc., f75373 Datasheet - Page 15

no-image

f75373

Manufacturer Part Number
f75373
Description
Fintek Hardware Monitor Ic Datasheet
Manufacturer
Feature Integration Technology Inc.
Datasheet
In both “FAN SPEED” and “TEMPERATURE” modes, F75373S adjust PWMOUT duty-cycle according to current
fan count and expected fan count. It will operate as follows:
(1). When expected count is FFFFh, PWMOUT duty-cycle will be set to 00h to turn off fan.
(2). When expected count is 0000h, PWMOUT duty-cycle will be set to FFh to turn on fan with full speed.
(3). If both (1) and (2) are not true and KEEP_DROP_DUTY(see INDEX 60h) is set to 0,
F75373S will keep duty-cycle at 00h 3 seconds
expected count in order to increase or decrease its duty-cycle. This ensures that if there is any glitch during the 3
seconds
at RAISE-DUTY 3 seconds
to increase or decrease its duty-cycle. This ensures that if there is any glitch during the 3 seconds
F75373S will ignore it.
Note 1: The period can be programmed at INDEX 6Eh.
5.4.3.3 PWMOUT Duty-cycle operating process
(a). When PWMOUT duty-cycle decrease to DROP_DUTY(≠ 00h), obviously the duty-cycle will be 00h next,
(b). When PWMOUT duty-cycle increase from 00h to RAISE_DUTY(≠ 00h), F75373S also will keep duty-cycle
Fintek
1
period, F75373S will ignore it.
1
. After that, F75373S starts to compare current fan count and expected count in order
1
. After that, F75373S starts to compare current fan count and
10
Feature Integration Technology Inc.
F75373
1
period,
V0.25P