6.7
Setting all ones to the high limits for voltages and fans (0111 1111 binary for temperature) means interrupts will never
be generated except the case when voltages go below the low limits.
Power on default: 00h
IRQ/SMI# ENABLE Register 1  Index 30h
Bit
7
6
5
4
3
2
1
0
Fintek
EN_FAN2_SMI
EN_FAN1_SMI
EN_VT2_SMI
EN_VT1_SMI
EN_V3_SMI
EN_V2_SMI
EN_V1_SMI
EN_VCC_SMI
2Ch
2Dh
2Bh
2Eh
2Fh
Name
Attribute
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Temperature sensor 2 Hysteresis Limit. The unit is 1
FAN1 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
FAN1 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
FAN2 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
FAN2 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
A one enables the corresponding interrupt status bit for SMI#
interrupt
A one enables the corresponding interrupt status bit for SMI#
interrupt.
A one enables the corresponding interrupt status bit for SMI#
interrupt.
A one enables the corresponding interrupt status bit for SMI#
interrupt.
A one enables the corresponding interrupt status bit for SMI#
interrupt.
A one enables the corresponding interrupt status bit for SMI#
interrupt.
A one enables the corresponding interrupt status bit for SMI#
interrupt.
A one enables the corresponding interrupt status bit for SMI#
17
Feature Integration Technology Inc.
Description
º
F75373
C.
V0.25P