f75363 Feature Integration Technology Inc., f75363 Datasheet - Page 14

no-image

f75363

Manufacturer Part Number
f75363
Description
?1o C Accuracy Temperature Sensor Ic With Fan Speed Control
Manufacturer
Feature Integration Technology Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
f753635G
Manufacturer:
FINTEK
Quantity:
20 000
Part Number:
f75363SG
Manufacturer:
FINTEK
Quantity:
20 000
Company:
Part Number:
f75363SG
Quantity:
2 300
7.2 Status Register  Index 02h
7.3 Status Register  Index 18h
F75363
Power on default <7:0> = 00h
Power on default <7:0> = 00h
T1 = On-chip temperature sensor (Local)
T1 = On-chip temperature sensor (Local)
Bit
4~3
7
6
5
4
3
2
1
0
2
1
0
ALERT_TACH_SEL
ALERT_QUEUE
T2_THERM_STS
T2_OPEN_STS
T1_HIGH_STS
T2_HIGH_STS
T1_LOW_STS
T2_LOW_STS
FAN_ALARM
ADC_BUSY
Reserved
Reserved
Name
Attribute
R/W
R/W
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
T2 = Pin 2 external temperature sensor (Remote)
T2 = Pin 2 external temperature sensor (Remote)
Set to 0, the F75363’s PWM output continues to output the control signal while in
standby. (when bit 6 is set to 1)
These bits are unused and always set to 0
Set to 1, pin6 is fan Tachometer input.
Set to 0, pin6 is ALERT output.
This bit is unused and always set to 0
Set to 1, an ALERT will be generated if consecutive abnormal events occur three times.
Set to 0, an ALERT will be generated if any abnormal event occurs.
Set to 1, ADC is converting.
Set to 1, T1 temperature exceeds high limit.
Set to 0, T1 temperature does not exceed high limit.
Set to 1, T1 temperature goes below low limit.
Set to 0, T1 temperature does not goes below low limit.
Set to 1, T2 temperature exceeds high limit.
Set to 0, T2 temperature does not exceed high limit.
Set to 1, T2 temperature goes below low limit.
Set to 0, T2 temperature does not goes below low limit.
Set to 1, T2 is open-circuit or shorted to VDD.
Set to 0, T2 is not open-circuit and not shorted to VDD.
Set to 1, T2 temperature exceeds its thermal limit.
Set to 0, T2 temperature does not exceed its thermal limit.
Set to 1, FAN count is higher than the FAN limit value
Set to 0, FAN count is equal or lower than the FAN limit value.
-10-
Description
F75363
July, 2007
V0.27P

Related parts for f75363