F75363
7.8 ALERT MASK Register 2  Index 17h
7.9 PWM Control Register  Index 30h
Power on default <7:0> = 23h
Power on default <7:0> = 00h
T1 = On-chip temperature sensor (Local)
Bit
5-4
Bit
6-0
7
6
5
4
3
2
1
0
Bit
7
6
3
2
7
T2_THR_MASK
T1_THR_MASK
FAN_MASK
FTK_MODE
T1H_MASK
T2H_MASK
T1L_MASK
T2L_MASK
Reserved
Reserved
Reserved
FLT_SEL
Reserved
Reserved
Reserved
Name
Name
Name
Attribute
Attribute
Attribute
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RO
RO
RO
RO
R/W
RO
T2 = Pin 2 external temperature sensor (Remote)
Fintek test mode used only
This bit is unused and always set to 1
Set to 1, T1 temperature exceeds high limit will not generate an ALERT.
Set to 0, T1 temperature exceeds high limit will generate an ALERT.
Set to 1, T1 temperature goes below low limit will not generate an ALERT.
Set to 0, T1 temperature goes below low limit will generate an ALERT.
Set to 1, T2 temperature exceeds high limit will not generate an ALERT.
Set to 0, T2 temperature exceeds high limit will generate an ALERT.
Set to 1, T2 temperature goes below low limit will not generate an ALERT.
Set to 0, T2 temperature goes below low limit will generate an ALERT.
This bit is unused and always set to 1
Set to 1, T2 temperature exceeds its thermal limit will not generate an ALERT.
Set to 0, T2 temperature exceeds its thermal limit will generate an ALERT.
Set to 1, FAN count exceeds its limit will not generate an ALERT.
Set to 0, FAN count exceeds its limit will generate an ALERT.
Set to 1, T1 temperature exceeds its thermal limit will not generate an ALERT.
Set to 0, T1 temperature exceeds its thermal limit will generate an ALERT.
Fintek test mode used only
Select method of controlling PWM duty and frequency to FINTEK mode.
This bit is unused and always set to 0
When bit7 set to 0, tachometer input filter can be selected here.
2’b00: Filter time = 177.6us
2’b01: Filter time = 355.2us
2’b10: Filter time = 888us
2’b11: Filter time = 1.776ms
This bit is unused and always set to 0