LT4256-1 LINER [Linear Technology], LT4256-1 Datasheet - Page 11

no-image

LT4256-1

Manufacturer Part Number
LT4256-1
Description
Positive High Voltage Hot Swap Controllers
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LT4256-1CGN
Manufacturer:
LT
Quantity:
1 155
Part Number:
LT4256-1CS8
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT4256-1CS8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT4256-1CS8#PBF
Manufacturer:
LT
Quantity:
3
Part Number:
LT4256-1CS8#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT4256-1CS8#TRPBF
Manufacturer:
LT
Quantity:
3 113
Part Number:
LT4256-1CS8#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT4256-1IS8
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT4256-1IS8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT4256-1IS8#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
APPLICATIO S I FOR ATIO
When the TIMER pin reaches 4.65V (typ), the internal fault
latch is set causing GATE to be pulled low and TIMER to be
discharged to GND by the 3 A current source. The part is
not allowed to turn on again until the voltage on TIMER
falls below 0.65V (typ).
TIMER must never be pulled high by a low impedance
because whenever TIMER rises above the upper threshold
(typically 4.65V) the pin characteristics change from a
high impedance current source to a low impedance.
Whenever GATE is commanded off by any fault condition,
it is discharged rapidly, turning off the external MOSFET.
The waveform in Figure 9 shows how the output latches off
following a current fault (LT4256-1). The drop across the
sense resistor is held at 55mV as the timer ramps up. Once
TIMER reaches its shutdown threshold (4.65V typically),
the circuit latches off.
The LT4256-1 latches off after a current limit fault. After
the LT4256-1 latches off, the part may be commanded to
500mA/DIV
50V/DIV
50V/DIV
5V/DIV
TIMER
GATE
V
I
OUT
OUT
Figure 9. LT4256-1 Current Limit Waveforms
U
10ms/DIV
U
W
4256 F09
U
start back up. This is accomplished by cycling UV to
ground and then back high (this command can only be
accepted after TIMER discharges back below the 0.65V
typical threshold, to prevent overheating transistor Q1).
Automatic Restart
The LT4256-2 will automatically restart after an overcurrent
fault. These waveforms are shown in Figure 10.
The LT4256-2 functionality is as follows: When an
overcurrent condition occurs, the GATE pin is servoed to
maintain a constant voltage across the sense resistor, and
the capacitor C2 at the TIMER pin will begin to charge.
When the voltage at the TIMER pin reaches 4.65V (typ),
the GATE pin is pulled low. When the voltage at the TIMER
pin ramps back down to 0.65V (typ), the LT4256-2 turns
on again. If the short-circuit condition at the output still
exists, the cycle will repeat itself indefinitely. The duty
cycle under short-circuit conditions is 3% which prevents
Q1 from overheating.
500mA/DIV
50V/DIV
50V/DIV
5V/DIV
TIMER
GATE
V
I
OUT
OUT
Figure 10. LT4256-2 Current Limit Waveforms
LT4256-1/LT4256-2
10ms/DIV
4256 F10
11
425612f