MY4 OMRON [Omron Electronics LLC], MY4 Datasheet - Page 16

no-image

MY4

Manufacturer Part Number
MY4
Description
General-purpose Relay
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MY4
Manufacturer:
OMRON
Quantity:
2 000
Part Number:
MY4 AC110/120 (S)
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
MY4 AC220/240 (S)
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
MY4-02-12VDC
Manufacturer:
RELAYS
Quantity:
5 400
Part Number:
MY4-02-24VDC
Quantity:
5 400
SEV Listings (File No. 99.5 50902.01)
Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may be different from the performance char-
PYF-S Installation Notes
■ Tools
A flat-blade screwdriver should be used to mount the cables.
Applicable Screwdriver
● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
Examples: FACOM AEF.2.5 × 75E
■ Applicable Wires
Applicable Wire Sizes
0.2 to 1.5 mm
Applicable Wire Type
Solid wires, stranded wires, flexible wires, or wires with ferules can
be used.
(See note 1.)
Conductor diameter d (mm) or length of sides a and b (mm) ≤ 1.9
274
● Flat-blade, Parallel-tip
● Flat-blade, Flared-tip
No. of poles
2
4
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.
2. In the interest of product improvement, specifications are subject to change.
2.5 dia. (3.0 mm max.)
acteristics individually defined in this catalog.
VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100)
WAGO 210-119
WIHA 260/2.5 × 40
Wires with Ferules
2
<
General-purpose Relay
, AWG24 to AWG16
2.2 ≤ Diameter D (mm) ≤ 3.2 (3.5: see note 2.)
Cannot be used.
Coil ratings
6 to 240 VAC
6 to 125 VDC
(AEF. 3 × 75E)
(260/3 × 50)
MY
Contact ratings
10 A, 250 VAC
10 A, 30 VDC
5 A, 250 VAC
5 A, 30 VDC
Note: 1. If the overall diameter of the wire is less than 2.2 mm, do not
2. If the overall diameter of the wire is over 3.2 mm, it will be
insert the wire past the conductor. Refer to the following di-
agrams.
difficult to use double wiring.
Operations
10 x 10
100 x 10
MY4Z AC; 50 x 10
3
3
3

Related parts for MY4