Preliminary Technical Data
SPECIFICATIONS
T
Table 1.
Parameter
TEMPERATURE SENSOR AND ADC
SUPPLIES
DIGITAL INPUT
DIGITAL OUTPUT
1
2
3
Thermal Time Constant is the time it takes for a starting temperature difference to change to 36.8% of it’s starting value. For example if the ADT7302 experienced a
thermal shock from 0°C to 100°C, it would take typically 2 secs for the ADT7302 to reach 63.2°C.
The ADT7302 is taken out of shutdown mode and a temperature conversion is immediately performed after this write operation. Once the temperature conversion is
complete, the ADT7302 is put back into shutdown mode.
Guaranteed by design and characterization, not production tested.
A
Accuracy
Temperature Resolution
Auto Conversion Update Rate, t
Temperature Conversion Time
Thermal Time Constant
Supply Voltage
Supply Current
Power Dissipation
Input High Voltage, V
Input Low Voltage, V
Input Current, I
Input Capacitance, C
Output High Voltage, V
Output Low Voltage, V
Output Capacitance, C
= T
Normal Mode
Shutdown Mode
Normal Mode (Average)
Shutdown Mode (Average)
MIN
1 SPS
10 SPS
100 SPS
to T
MAX
3
3
IN
, V
DD
IL
IN
= 2.7 V to 5.5 V, unless otherwise noted. All specifications apply for –40°C to +125°C, unless otherwise stated
IH
OL
OUT
OH
1
2
R
Min
2.7
2.5
V
DD
− 0.3 V
Typ
TBD
TBD
TBD
0.03125
1
2
2
1.6
190
1.6
280
0.2
0.2
631
1.41
4.88
7.4
42.9
65
423
641
Rev. PrE | Page 3 of 14
Max
±2
±2.5
±3
5.5
2.2
300
2.2
400
1
1
0.8
±1
10
0.4
50
Unit
°C
°C
°C
°C
sec
ms
sec
V
mA
µA
mA
µA
µA
µA
µW
mW
µW
µW
µW
µW
µW
µW
V
V
µA
pF
V
pF
Test Conditions/Comments
V
T
T
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
All digital inputs
I
I
T
Temperature measurement every 1 second
For Specified performance.
SOURCE
OL
A
A
A
DD
DD
DD
DD
DD
DD
DD
DD
DD
DD
DD
DD
DD
DD
DD
IN
= 0°C to 70°C.
= −20°C to +85°C.
= −40°C to +125°C.
= 200 µA
= 0 V to V
= +3.3 V (±10%) and 5 V (±10%)
= 3.3 V. Powered up and converting
= 3.3 V. Powered up and not converting
= 5 V. Powered up and converting
= 5 V. Powered up and not converting
= 3.3 V.
= 5 V.
= 3.3 V. Auto conversion update, t
= 5 V. Auto conversion update, t
= 3.3 V
= 5 V
= 3.3 V
= 5 V
= 3.3 V
= 5 V
= I
SINK
= 200 µA
DD
R
.
ADT7302
R
.