ADuM2250ARIZ-RL AD [Analog Devices], ADuM2250ARIZ-RL Datasheet - Page 6

no-image

ADuM2250ARIZ-RL

Manufacturer Part Number
ADuM2250ARIZ-RL
Description
Hot-Swappable, Dual I2C Isolators, 5 kV
Manufacturer
AD [Analog Devices]
Datasheet
ADuM2250/ADuM2251
PACKAGE CHARACTERISTICS
Table 3.
Parameter
Resistance (Input to Output)
Capacitance (Input to Output)
Input Capacitance
IC Junction-to-Ambient Thermal Resistance
1
REGULATORY INFORMATION
The ADuM2250/ADuM2251 is approved by the following organizations.
Table 4.
UL
Recognized under 1577
Single Protection
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 5.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap
Minimum External Tracking (Creepage) RW-16 Package
Minimum External Tracking (Creepage) RI-16 Package
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
The device is considered a 2-terminal device; Pin 1 to Pin 8 are shorted together, and Pin 9 to Pin 16 are shorted together.
In accordance with UL1577, each ADuM225x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 µA).
In accordance with DIN V VDE V 0884-10, each ADuM225x is proof tested by applying an insulation test voltage ≥1590 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Component Recognition
Program
5000 V rms Isolation Voltage
1
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-07 and IEC 60950-1, 600 V
rms (848 V peak) maximum working voltage
RW-16 package.
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1,
380 V rms (537 V peak) maximum working voltage; reinforced
insulation per IEC 60601-1 125 V rms (176 V peak) maximum
working voltage
RI-16 package
Reinforced insulation per CSA 60950-1-07 and IEC 60950-1,
400 V rms (565 V peak) maximum working voltage; reinforced
insulation per IEC 60601-1 250 V rms (353 V peak) maximum
working voltage.
File 205078
Symbol
R
C
C
θ
I-O
JA
I-O
I
Symbol
L(I01)
L(I02)
L(I02)
CTI
Rev. A | Page 6 of 16
Min
Value
5000
8.0 min
7.7 min
8.3 min
0.017 min
>175
IIIa
Typ
10
2.2
4.0
45
12
Unit
V rms
mm
mm
mm
mm
V
Max
Conditions
1-minute duration
Distance measured from input terminals to output
terminals, shortest distance through air along the
PCB mounting plane, as an aid to PC board layout
Measured from input terminals to output
terminals, shortest distance path along body
Measured from input terminals to output
terminals, shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Unit
Ω
pF
pF
°C/W
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
Reinforced insulation, 846 V peak
File 2471900-4880-0001
Test Conditions
f = 1 MHz
Thermocouple located at center of
package underside
Data Sheet