ADUM3301 AD [Analog Devices], ADUM3301 Datasheet - Page 10

no-image

ADUM3301

Manufacturer Part Number
ADUM3301
Description
Triple-Channel, Digital Isolators, Enhanced System-Level ESD Reliability
Manufacturer
AD [Analog Devices]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3301ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM3301ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM3301BRWZ
Manufacturer:
SMD
Quantity:
6 239
Part Number:
ADUM3301BRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM3301CRWZ
Manufacturer:
ADI
Quantity:
250
Part Number:
ADUM3301CRWZ
Manufacturer:
AD
Quantity:
6 877
Part Number:
ADUM3301CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM3300/ADuM3301
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input to Output)
Capacitance (Input to Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
2
REGULATORY INFORMATION
The ADuM330x is approved by the organizations listed in Table 5.
Table 5.
UL
Recognized under 1577 component
recognition program
Double/reinforced insulation,
2500 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Device considered a 2-terminal device; Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15, and
Pin 16 shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL1577, each ADuM330x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
In accordance with DIN EN 60747-5-2, each ADuM330x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection limit =
5 pC). The * marking branded on the component designates DIN EN 60747-5-2 approval.
1
2
1
1
1
CSA
Approved under CSA
Component Acceptance Notice #5A
Reinforced insulation per
CSA 60950-1-03 and IEC 60950-1,
400 V rms maximum working voltage
File 205078
Symbol Value
L(I01)
L(I02)
CTI
Symbol
R
C
C
θ
θ
I-O
I-O
I
JCI
JCO
Rev. 0 | Page 10 of 20
2500
7.7 min
8.1 min
0.017 min mm
>175
IIIa
Min
Unit
V rms 1-minute duration
mm
mm
V
Typ
10
2.2
4.0
33
28
12
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
VDE
Certified according to
DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01
Basic insulation, 560 V peak
Complies with
DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950: 2000
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Max
2
Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
2

Related parts for ADUM3301