SIG
special DC bias network that enables AC coupling of
input signals. If the signals are not AC coupled,
standard SL74HC input levels are required. Both input
structures are shown in Figure 6. The outputs of these
the SL74HC86. Its operation is similar to an overdriven
balanced modulator. To maximize lock range the input
frequencies must have a 50% duty cycle. Typical input
and output waveforms are shown in Figure 7. The
output of the phase detector feeds the loop filter which
averages the output voltage. The frequency range
upon which the PLL will lock onto if initially out of lock
is defined as the capture range.The capture range for
phase detector 1 is dependent on the loop filter design.
The capture range can be as large as the lock range,
which is equal to the VCO frequency range.
Figure 7. When two square wave signals are applied to
this comparator, an output waveform (whose duty
cycle is dependent on the phase difference between
the two signals) results. As the phase difference
increases, the output duty cycle increases and the
voltage after the loop filter increases. In order to
achieve lock when the PLL input frequency increases,
the VCO input voltage must increase and the phase
difference between COMP
an input frequency equal to f
V
IN
and COMP
Phase Comparators
All three phase comparators have two inputs,
Phase Comparator 1
This comparator is a simple XOR gate similar to
To see how the detector operates, refer to
IN
. The SIG
IN
and SIG
min
IN
, the VCO input is at 0
and COMP
Figure 6. Logic Diagram for Phase Comparators
IN
will increase. At
IN
have a
comparators are essentially standard SL74HC outputs
(comparator 2 is TRI-STATEABLE). In normal
operation V
loop filter. This differs from some phase detectors
which supply a current to the loop filter and should be
considered in the design.
grounded; hence, the two input signals must be in
phase. When the input frequency is f
input must be V
be 180 degrees out of phase.
harmonics of the SIG
2. For instance, a signal 2 times the VCO frequency
results in the same output duty cycle as a signal equal
to the VCO frequency. The difference is t h at the
output frequency of the 2f example is twice that of the
other example. The loop filter and VCO range should
be designed to prevent locking on to harmonics.
Figure 7. Typical Waveforms for PLL Using
This requires the phase detector output to be
The XOR is more susceptible to locking onto
CC
and ground voltage levels are fed to the
CC
Phase Comparator 1
and the phase detector inputs must
IN
than the digital phase detector
max
, the VCO
488