HIP0082 Intersil Corporation, HIP0082 Datasheet - Page 5

no-image

HIP0082

Manufacturer Part Number
HIP0082
Description
Quad Power Drivers with Serial Diagnostic Interface
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HIP0082
Manufacturer:
ST
0
Part Number:
HIP0082
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
HIP0082AB
Manufacturer:
HARRIS
Quantity:
20 000
Part Number:
HIP0082AS1
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
HIP0082AS1
Manufacturer:
PANASONIC
Quantity:
5 510
Part Number:
HIP0082AS1
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
HIP0082AS2
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
HIP0082ASI
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
HIP0082ASI
Manufacturer:
IR
Quantity:
5 510
Part Number:
HIP0082ASI
Manufacturer:
ST
0
Electrical Specifications
NOTES:
10. Measurement includes the Filter Time.
OPEN LOAD DETECTION
Output ON Resistance in
High r
Detection Mode
Max. Output Current in High
r
Min. Output Current in Low
r
(Hysteresis Range)
Open-Load Fault Threshold
Open-Load Detection Pull-up
Resistance
Open-Load Delay Time
after INx H L
Open-Load Delay Time
after INx H L
Open Load Filter Time
OVER TEMPERATURE AND SHORT CIRCUIT PROTECTION
Over Temperature Detection
Threshold
Output Short-to-Gnd
Threshold
Short-to-GND Filter Time
SERIAL INTERFACE (Figure 3) C
Serial Clock Frequency
Propagation Delay CLK to
Data Valid
Setup Time, CS to CLK
CS Low to Data Valid
Hold Time CS after CLK
CS High to Output High Z
Minimum Time CLK = High
Minimum Time CLK = Low
Setup Time R/W Low to CLK
R/W Low to Output High Z
Setup Time Data Valid to
CLK Low
Setup Time R/W High to CLK
Time R/W High to Data Valid
8. Each Output has Over Current Shutdown protection in the positive current direction. The maximum peak current rating is set equal to the
9. The “Low V
DS(ON)
DS(ON)
minimum Over Current Shutdown as detailed in the Electrical Specification Table. In the event of an Over Current Shutdown the input
drive is latched OFF. The output short must be removed and the input toggled OFF and ON to restore the output drive.
DS(ON)
PARAMETER
Normal Mode
Mode
Open-Load
CC
Shutdown” is an internal control that switches off all power drive stages when V
r
r
r
r
DS(ON)1OL
DS(ON)2OL
DS(ON)3OL
DS(ON)4OL
SYMBOL
t
I
t
t
t
t
t
RWHCLK
t
OL(MAX)
I
RWLCLK
t
PCLKDV
t
CLKCSH
t
CSLCLK
DVCLKL
RWHDV
O(HYS)
t
CSHDZ
RWLDZ
t
CSLDV
t
T
t
DOLH
I
DOLL
f
CLKH
R
V
CLKL
t
OLF
t
CLK
TMP
V
SG
OL
SG
OL
CC
EXT
= 5V 10%, T
= 50pF
Outputs 1 and 2, One Output ON,
I
Outputs 3 and 4, One Output ON,
I
(ISC Bit is set in Fault Register)
Td_OLx Bit = Low
Td_OLx Bit = High (Note 10)
50% Duty Cycle
OUT
OUT
= 10mA, T
= 10mA, T
TEST CONDITIONS
A
HIP0082, HIP0084
= -40
J
J
o
= 150
= 150
C to 125
o
o
C
C
5
o
C; Unless Otherwise Specified (Continued)
0.25 x
(MAX)
MIN
340
150
155
150
150
150
100
100
150
100
I
2.4
90
20
OL
3
2
3
-
-
-
-
-
-
-
-
HIP0082
TYP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.95 x
(MAX)
MAX
180
580
252
165
252
150
100
100
100
100
6.2
5.7
I
6.5
5.2
2.9
20
CC
OL
3
-
-
-
-
-
-
-
is less than V
MIN
340
150
155
150
150
150
100
100
150
100
2.4
15
20
3
-
-
-
-
-
-
HIP0084
TYP
N/A
NA
NA
2.6
60
CC(LOW)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MAX
100
580
252
165
252
150
100
100
100
100
5.2
2.9
.
3
-
-
-
-
-
-
-
UNITS
MHz
mA
mA
mA
k
ms
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
V
C
s
s
s

Related parts for HIP0082