SMQ300PS18-C XPPOWER [XP Power Limited], SMQ300PS18-C Datasheet

no-image

SMQ300PS18-C

Manufacturer Part Number
SMQ300PS18-C
Description
AC-DC Power Supplies
Manufacturer
XPPOWER [XP Power Limited]
Datasheet
300/400 Watts
SMQ Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • <2.5 mA at 230 VAC/50Hz
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 115-130% Vnom, recycle input to reset
Overcurrent Protection • 120-150% of nominal current,
Overtemperature
Protection
Remote Sense
Remote On/Off
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 5.00 A at 90 VAC (SMQ300),
• 35 A max at 230 VAC
• 0.99 typical
• 12 to 54 VDC - see table
• See table
• No minimum load required
• 2.5 s typical at 120 VAC
• 20 ms minimum at 120 VAC & 80% load
• ±1%
• ±1%
• 5% max. deviation, recovery to within
• 1% pk-pk, 20 MHz BW
• Unit shuts down, auto recovery
• Compensates for up to 0.5 V drop
• On = TTL Logic High or Open circuit
6.35 A at 90 VAC (SMQ400)
<1.5 mA at 115 VAC/60Hz
1% in 500 µs for a 50% load change
auto recovery
Off = TTL Logic Low or Short circuit
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from
Cooling
Operating Humidity
Storage Temperature
Shock
Vibration
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
High Power Density
High Peak Load Rating
DC OK
Remote On/Off
Universal Input
Single Outputs from 12.0 V to 54.0 V
Internal Fan
• 80% typical
• 3000 VAC Input to Output,
• 60 kHz typical for PFC stage,
• 4.7 W/In
• DC OK, TTL HIGH within 100-500 ms
• 138 kHrs per MIL-HDBK-217F
• Via internal fan
• 5-90% RH, non-condensing
• -20 ˚C to +85 ˚C
• 15 g (non-operation), 11 ms half
• 10 Hz - 55 Hz (non-operation) 2 g,
• EN55022 and FCC Part 15,
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 contact, level 3 air,
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, level 2, Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
• UL60950, CSA C22.2 No.60950,
1500 VAC Input to Ground,
250 VDC Output to Ground
30 kHz typical for main converter
LOW 1 ms before loss of regulation
100% at +50 ˚C to 50% at +70 ˚C
sine-wave, 3 times for each axis
sweep time 3 mins, 60 mins/axis
level B conducted
Perf Criteria A
100% 5000 ms Perf Criteria A, B, B
EN60950, CE Mark LVD
3
(SMQ300), 6.25 W/In
xppower.com
3
(SMQ400)

Related parts for SMQ300PS18-C

SMQ300PS18-C Summary of contents

Page 1

Watts SMQ Series Specification Input Input Voltage • 90-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz Input Current • 5. VAC (SMQ300), 6. VAC (SMQ400) Inrush Current • max at ...

Page 2

... 1.80 (45.72) 2.50 (63. 1.10 (27.94) 0.75 (19.05) 8.00 (203. SMQ Output Current Model Number Peak (2) 46.66 A SMQ300PS12-C†^ 46.66 A SMQ300PS15-C†^ 33.33 A SMQ300PS18-C 23.33 A SMQ300PS24-C†^ 23.33 A SMQ300PS27-C 17.07 A SMQ300PS36-C 12.72 A SMQ300PS48-C†^ 12.72 A SMQ300PS54-C 46.66 A SMQ400PS12-C†^ 46.66 A SMQ400PS15-C†^ 33.33 A SMQ400PS18-C 23.33 A SMQ400PS24-C†^ 23.33 A SMQ400PS27-C 17.07 A SMQ400PS36-C 12.72 A SMQ400PS48-C†^ 12.72 A SMQ400PS54-C A Mounting Hole 8 Places ...

Related keywords