ACX306BKM SONY [Sony Corporation], ACX306BKM Datasheet

no-image

ACX306BKM

Manufacturer Part Number
ACX306BKM
Description
3.86cm (1.5-type) NTSC/PAL Color LCD Panel Module with LED Backlight
Manufacturer
SONY [Sony Corporation]
Datasheet
Description
backlight developed exclusively for the ACX306BKM
3.86cm diagonal active matrix TFT-LCD panel
addressed by low temperature polycrystalline silicon
transistors with built-in peripheral driving circuitry.
NTSC and PAL systems. In addition, RGB dots are
arranged in a delta pattern that provides smooth
picture quality without fixed color patterns compared
to vertical stripe and mosaic patterns.
Features
• Total module thickness: 3.9mm (typ.) ultra-thin, narrow frame type
• Center luminance
• White LED backlight eliminates the need for an inverter, achieves instant luminance rise, and maintains high
• Backlight life (luminance half-life) guaranteed at 5000h for normal temperature operation and 1000h for high
• Number of active dots: 118,000, 3.86cm (1.5-type) in diagonal
• Horizontal resolution:
• Optical transmittance:
• High contrast ratio with normally white mode: 200 (typ.)
• Built-in H and V driving circuitry (built-in input level conversion circuit, 3V drive possible)
• Low voltage, low power consumption: 12V drive, 43mW (panel block, typ.)
• Smooth pictures with a RGB delta arrangement
• Supports NTSC/PAL
• Built-in picture quality improvement circuit
• Up/down and/or right/left inverse display function
• LR (low reflectance) surface treatment provides an easy-to-see display even outdoors
• Dirt-resistant surface treatment
• Narrow frame
Element Structure
• Active matrix TFT-LCD panel with built-in peripheral driving circuitry using low temperature polycrystalline
• Edge-light type backlight using high luminance white LEDs
• Number of pixels
• Module dimensions
Applications
The ACX306BKM is an LCD panel module with LED
This module provides full-color representation for
luminance even at cold temperatures
temperature operation
silicon transistors
Compact digital still cameras, compact video cameras, etc.
3.86cm (1.5-type) NTSC/PAL Color LCD Panel Module with LED Backlight
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
Total number of dots:
Number of active dots:
Package dimensions:
Effective display dimensions: 31.115 (H)
Standard mode:
High luminance mode: 330cd/m
240 TV lines
9.0% (typ.)
494 (H)
490 (H)
37.1 (W)
242 (V) = 119,548
240 (V) = 117,600
32.7 (D)
260cd/m
22.86 (V) (mm)
– 1 –
2
2
3.9 (H) (mm)
(backlight 210mW typ.)
(backlight 290mW typ.)
ACX306BKM
E00X53A14

Related parts for ACX306BKM

ACX306BKM Summary of contents

Page 1

... NTSC/PAL Color LCD Panel Module with LED Backlight Description The ACX306BKM is an LCD panel module with LED backlight developed exclusively for the ACX306BKM 3.86cm diagonal active matrix TFT-LCD panel addressed by low temperature polycrystalline silicon transistors with built-in peripheral driving circuitry. ...

Page 2

... Module Configuration Panel Block Diagram The panel block diagram is shown below. Level Shifter Common Voltage Boost, Negative Voltage Generation Circuit – 2 – ACX306BKM COM ...

Page 3

... Typ. Max 12.0 12.6 12.0 — 15.0 16.3 –1.8 –1.5 10 160 Recommended voltage applied example Zener diode 1µF (RD2.7UM is recommended Recommended voltage applied 1µF example Zener diode (RD4.3UM is recommended.) ACX306BKM °C ° 0V) SS Unit ...

Page 4

... SS Typ. Max. Unit 0.0 0.3 V 3.0 5.5 V VIH/2 VIH/2 + 0.3 V 6.0 6.2 V VVC ± 4.0 VDDG – 2.0 V VVC ± 2.5 VVC ± 2.7 V VVC – 0.5 VVC – 0.4 V Typ. Max. Unit 15 — mA 13.9 15.5 V 209 233 mW Typ. Max. Unit 20 — mA 14.4 16.0 V 288 320 mW ACX306BKM ...

Page 5

... Clock input for H shift register drive 18 PSIG Uniformity improvement signal input 19 GREEN Video signal (G) input to panel 20 RED Video signal (R) input to panel 21 BLUE Video signal (B) input to panel 22 H shift register drive direction RGT 23 signal input TESTR Panel test output; no connection 24 – 5 – ACX306BKM Description ...

Page 6

... V DD 175 Input REF (5) RGT, REF Input REF Signal line V H level shifter and shift register circuit 350 Level conversion circuit 175 Level conversion circuit Level conversion circuit 1M 1M – 6 – ACX306BKM with SS ...

Page 7

... VDDG, VSSG (9) COM (10) Cext/Rext Cext/Rext (11) TEST/TEST2 TEST (12) TESTL, TESTR 800 Boost, Negative voltage generation circuit Input 350 350 1M 4M TESTL TESTR – 7 – Level conversion circuit V DD Level conversion circuit driver TEST2 ACX306BKM ...

Page 8

... ACX306BKM Unit µs ns µs 1.6 ...

Page 9

... Horizontal Standard Timing HST HCK1 HCK2 FRP VCK EN WIDE 3.0µs 0.6µs 3.0µs 1.1µs 0.4µs 1.5µs – 9 – ACX306BKM ...

Page 10

... WIDE 10% tfWide trWide 6 tdhWide VCK 50% WIDE twhWide twhWide tdhWide ) means +. ) means –. ) indicates the start of measurement. – 10 – ACX306BKM Conditions 90% 5 • HCKn duty cycle 50% 10% to1Hck = 0ns to2Hck = 0ns tfHst 50% 5 • HCKn duty cycle 50% to1Hck = 0ns to2Hck = 0ns 5 • ...

Page 11

... Vertical Standard Timing NTSC 4:3 (in case of EVEN field) VST VCK FRP HST EN WIDE – 11 – ACX306BKM ...

Page 12

... VCK 10% tfVck trVck trEn 90% 10% EN tfEn tfEn 6 tdEn VCK 50% EN twEn tdEn – 12 – ACX306BKM Conditions 90% • VCK duty cycle 50% to1Vck = 0ns 10% to2Vck = 0ns tfVst 50% • VCK duty cycle 50% to1Vck = 0ns 50% to2Vck = 0ns thVst • VCK duty cycle 90% 50% to1Vck = 0ns ...

Page 13

... Typ. Max. PWR25 — PWR60 — — 75 Symbol Min. Typ. Max. Rin1 0.5 1 — – 13 – ACX306BKM = 12.0V, VIH = 3.0V, VREF = 1.5V) Unit Conditions µA HCK1: actual driving µA HCK2: actual driving µA HST = GND µA RGT = GND µA REF = VIH/2 Unit ...

Page 14

... F 8 60°C YT1 0° 25°C CTK – 14 – ACX306BKM (Ta = 25°C, NTSC mode) Min. Typ. Max. Unit 100 200 — 7.8 9.0 — 180 260 — cd/m 240 330 — — 0.295 0.325 CIE standard — ...

Page 15

... Tcbl duvbl BLunif Ta = less than BLl 1555 55°C BLl 70°C 1570 Ta = less than BLl 2040 40°C BLl 60°C 2065 – 15 – ACX306BKM (Ta = 25°C, discrete backlight) Min. Typ. Max. 12 12.3 13.9 15.5 12 12.8 14.4 16.0 12 185 209 233 12 256 288 ...

Page 16

... Both luminosities are measured by System I. : signal amplitude) Luminance TOPCON BM-5A luminance meter Meter Constant V current circuit Optical fiber Surface A Measure using the discrete LCD panel. Light Source Light Source Optical fiber Spectroscope Surface A = 4.0V. AC – 16 – Measurement Light Detector Equipment Surface A: See the Package Outline. = 0.5V. AC ACX306BKM ...

Page 17

... AC G input B input 4.0 4.0 0.5 4.0 4.0 0.5 0.0 0.0 (Unit and 100 50 and V , that 50RG 50BG and V and 50R 50G 0 – 17 – ACX306BKM – Signal amplitude [ 50RG V 50BG G raster R raster B raster V V 50R 50B V 50G V – Signal amplitude [V] AC ...

Page 18

... Vsig = 6.0 ± 4.0 or 6.0 ± 2.0 [V] (shown in the figure to the right) VCOM = 5.5V Input signal voltage (Waveform applied to measured pixels) 4.0V 0.5V 5.5V 0V Optical transmittance output waveform 100% 90% 10 that holds the maximum image retention, AC Black level 4.0V White level 2.0V 6.0V 2.0V 0V Vsig waveform – 18 – ACX306BKM tON t1 tOFF t2 ton toff [V] 4.0V ...

Page 19

... Cross talk is determined by the luminance differences between adjacent areas represented by Wi' and around the black window (Vsig = 4.0V/1V W2' W4' W3 W3' Bottom Wi' – Wi Cross talk value CTK = Wi – 19 – Normal ( = 0˚ Left Top Right Surface A 100 [%] ACX306BKM 100 [%] ...

Page 20

... Continuous lighting at an ambient temperature of 70°C. (1000h or more) (2) Ifbl = 20mA 2-1) Continuous lighting at an ambient temperature of 40°C. (5000h or more) 2-2) Continuous lighting at an ambient temperature of 65°C. (1000h or more) Effective pixel area of the panel 1/3 1/3 1 – 20 – ACX306BKM ...

Page 21

... 490 494 – 21 – Gate SW Gate ACX306BKM ...

Page 22

... VST VCK (3) Horizontal display period (RGT: high level) BLK HST HCK1 HCK2 2 1 Vertical display period 240H (14.5ms Vertical display period 240H (14.5ms) 165 164 166 Horizontal display period (54.6µs) – 22 – ACX306BKM 490 pixels to 240 239 239 240 ...

Page 23

... Two methods are applied for the delaying procedure: Sample-and-hold and Delay circuit. These two block diagrams are as follows. The ACX306BKM has a right/left inversion function. The following phase relationship diagram indicates the phase setting for right scan (RGT = high level). For left scan (RGT = low level), the phase setting should be inverted for the B and G signals ...

Page 24

... COM HST HCK1 HCK2 LCD panel VST ACX306BK VCK DWN EN RGT REF WIDE Dedicated LED backlight LCD module with backlight – 24 – ACX306BKM Rext Cext See page 3 for the value setting. Zener diode RD4.3UM VDDG 1µF Zener diode RD2.7UM VSSG 1µF ...

Page 25

... Use a design that does not repeatedly bend or place stress on the backlight lead wires (maximum load in the lead wire pull-out direction: 500g) as this may cause lead wire disconnection at the solder junction on the backlight unit side. (Forced bending of 90° or more is permitted times, and repeated bending of 45° times.) – 25 – ACX306BKM ...

Page 26

... Keep the panel and backlight away from heat sources not dampen the panel or backlight with water or other solvents. f) Avoid storage or use of the panel at high temperatures or high humidity, as this may result in damage. Polarizer package Guaranteed area 0.7mm Effective display area Fig. 1 – 26 – ACX306BKM ...

Page 27

Package Outline Unit: mm 37.1 ± 0.3 (Bending portion) 36.56 ± 0.1 (Corner portion) (1.13) 1.13 Corner portion (4 places) 34.3 (Window) C portion enlarged 33.3 ± 0.4 (Polarizer) 31.115 (Active area) C 18.55 Front View (Surface A) (Pink) 3 ...

Page 28

... This datasheet has been download from: www.datasheetcatalog.com Datasheets for electronics components. ...