State Definitions
Primary Control Modes
Powerup, Forward Battery
Powerup, Reverse Battery
Agere Systems Inc.
Normal talk and battery feed state.
Pin PT is positive with respect to pin PR.
All ac transmission and dc feed circuits are powered
up.
On-hook transmission is enabled.
Thermal shutdown is active.
Battery window comparator sense shutdown is on.
Switch break switches (SW1 and SW2) are closed,
and ring access switches (SW3 and SW4) are open.
V
tions.
Automatic battery switch selects V
ing off-hook conditions.
All supervision circuits except for ring trip detector
are active.
TESTLEV output is in the high-impedance mode,
and TESTSIG input is off unless this feature is
selected via the secondary control table.
NSTAT represents the loop closure detector status.
Normal talk and battery feed state.
Pin PR is positive with respect to pin PT.
All ac transmission and dc feed circuits are powered
up.
On-hook transmission is enabled.
Thermal shutdown is active.
Battery window comparator sense shutdown is on.
Switch break switches (SW1 and SW2) are closed,
and ring access switches (SW3 and SW4) are open.
V
tions.
Automatic battery switch selects V
off-hook conditions.
All supervision circuits except for ring trip detector
are active.
BAT1
BAT1
is applied to tip and ring during on-hook condi-
is applied to tip and ring during on-hook condi-
BAT1
BAT1
or V
or V
BAT2
BAT2
under
dur-
Scan
Ground Start
Ringing
TESTLEV output is in the high-impedance mode,
and TESTSIG input is off unless this feature is
selected via the secondary control table.
NSTAT represents the loop closure detector status.
Scan clamp circuitry is active.
Loop closure is active.
All ac transmission, dc feed, and other supervision
circuits, including ring trip, are shut down.
Thermal shutdown is active.
Battery window comparator sense shutdown is on.
On-hook transmission is disabled.
Pin PT is positive with respect to PR and V
applied to tip/ring.
Switch break switches (SW1 and SW2) are closed,
and ring access switches (SW3 and SW4) are open.
NSTAT represents the loop closure detector status.
Tip amplifier is on, tip break switch is open.
The device presents a high impedance (>100 k ) to
pin PT and a current-limited battery (V
Common-mode current detector is on.
Ring trip detector is off.
Output RGDET indicates current flowing in the ring
lead.
This is not a defined state in the primary control
mode table. It is achieved via the powerup and the
ring amp states in the primary control mode table.
Switch break switches (SW1 and SW2) are open,
and ring access switches (SW3 and SW4) are
closed.
Tip/ring drive amplifiers are powered down.
Ring trip circuit is active.
Loop supervision and common-mode current detec-
tors are powered down.
NSTAT represents the ring trip detector status.
Ringing Relay, and GR-909 Test Access
BAT2
) to PR.
BAT1
is
13