IMP8-1A0-00-A-XXX ASTEC [Astec America, Inc], IMP8-1A0-00-A-XXX Datasheet - Page 2

no-image

IMP8-1A0-00-A-XXX

Manufacturer Part Number
IMP8-1A0-00-A-XXX
Description
Intelligent MP Series Up to 1500 Watts
Manufacturer
ASTEC [Astec America, Inc]
Datasheet
Output Module Line-up
*Programmable
Output
Adjustment range*
Margining
Overall reg
Ripple
Dynamic response
Recovery time
Overcurrent protection* Configurable through I I
Short circuit protection
Overvoltage protection* Configurable through I
Reverse voltage protection 100% of rated output current
Thermal protection*
Remote sense
Singlewire parallel
Minimum load
Housekeeping bias voltage 5 VDC @1.0Amp max. present whenever AC input is applied
Module inhibit*
Switching frequency
Output/Output isolation
VME signal*
*Can be controlled via I
D D C C O O K K * *
Module Code
Module Type
Max output power
Max output current
Output voltages available*
Standard voltage increments
Remote sense
Remote margin
V-Program - I
Active Current Share
Module Inhibit - I
Module Inhibit - Analog
Over voltage / Over current protection
Minimum load required
Slots occupied in any iMP case
Single output module
Dual output module
Triple output module
2
C Control
2
C Control
2
C
±10% minimum all outputs (manual)
(full module adjustment range using I I
±4-6% nominal analog (single output module only)
0.4% or 20 mV max. (36W modules 4% max.)
RMS: 0.1% or 10 mV, whichever is greater
Pk-Pk: 1.0% or 50 mV, whichever is greater
Bandwidth limited to 20 MHz
<2% or 100 mV, with 25% load step
To within 1% in <300 μsec.
put of the dual output module 105-120% of rated output cur-
rent. Aux output of dual output module 105-140% of rated
output current
Triple output module internally protected
Protected for continuous short circuit
Recovery is automatic upon removal of short
2-5.5V 122-134% ; 6-60V 110-120%
2-6V 122-134% ; 8-28V 110-120%
No overvoltage protection provided
Configurable through I I
All outputs disabled when internal temp exceeds safe operat-
ing range. >5 ms warning (AC OK signal) before shutdown
Up to 0.5 V total drop (not available on triple output module)
Configurable through firmware
Current share to within 2% of total rated current
+/-5% of nominal. Configurable through I I
Not required
Configured and controlled through I I
250 kHz accepts external sync signal
>1 Megohm, 500V
DC OK signal programmable through I I
as POR signal
S S i i n n g g l l e e
210W
2-60V
35A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
25
1 1
1
S S i i n n g g l l e e
360W
2-60V
60A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
25
No
2 2
2
2 2
2 2
2
C C . Single output module and main out-
C
C C
2-60V
S S i i n n g g l l e e
750W
150A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
25
3 3
3
2 2
C C
2 2
C C )
2 2
5, 12-15, 28-30V 2-6, 12-15, 28-30V 8-15V 8-28V 2-28V
C C to function
2 2
C C
Yes
Yes
Yes
Yes
Yes
No
No
No
144W
D D u u a a l l
10A
19
4 4
1
Yes
Yes
Yes
Yes
No
No
No
No
Environmental
Specifications
Safety
Operating
temperature
Storage
temperature
Electromagnetic
susceptibility
Humidity
Vibration
MTBF
demonstrated
UL
CSA
VDE
BABT Compliance to
CB
CE
UL60950/UL2601
CSA22.2 No. 234 Level 5
EN60950/EN60601
EN 60950/EN60601 BS 7002
Certificate and report
Mark to LVD
Yes
Yes
Yes
No
No
No
No
No
N N o o n n e e
T T r r i i p p l l e e
36W
Yes
Yes
Yes
No
No
No
No
No
each output 2.5% per degree
from 50° to 70°C.
( -20°C start up)
Designed to meet EN61000-
4; -2, -3, -4, -5, -6, -8, -11
Level 3
Operating; non-condensing
10% to 95% RH
IEC68-2-6 to the levels of
IEC721-3-2
220VAC and 25°C ambient
conditions
2A
18
-40° to 70°C ambient. Derate
-40°C to +85°C
>550,000 hours at full load,
1
Yes
Yes
Yes
No
No
No
No
No
Rev. 1.30.06
iMP Series
2 of 8

Related parts for IMP8-1A0-00-A-XXX