IMP8-1A0-00-A-XXX ASTEC [Astec America, Inc], IMP8-1A0-00-A-XXX Datasheet - Page 8

no-image

IMP8-1A0-00-A-XXX

Manufacturer Part Number
IMP8-1A0-00-A-XXX
Description
Intelligent MP Series Up to 1500 Watts
Manufacturer
ASTEC [Astec America, Inc]
Datasheet
iMP Case Specifications
iMP8 8 =2.5" x 7" x 10" 6 available slots
iMP1 1 =2.5" x 8" x 11" 7 available slots
iMP4 4 =2.5" x 5" x 10" 5 available slots
iMP8 and iMP1
iMP4
Pin Connectors
Mates with
Landwin 2050S/000 Housing
Figure 1. AC Input
Figure 2. Connector J1
Mates with
Molex 90142-0010
Amp 87977-3
Figure 3. Connector J2
10
6
1
1
2
3
9
O
5
S
L
T
(63.5 x 127 x 254)
(63.5 x 177.8 x 254)
(63.5 x 203.2 x 279.4)
iMP1 only
~
N
2053T011P Pin
O
4
S
T
L
O
S
L
T
7
O
S
T
3
L
O
6
S
L
T
5
10
2
1
O
2
S
L
T
O
5
S
L
T
AC Input
Pin No. Function
1
2
3
PFC Input Connector (control and signals)
Pin No. Function
1
2
3
4
5
6
7
8
9
10
I
Pin No. Function
1
2
3
4
5
6
7
8
O
S
T
1
2
L
C Bus Output Connector
O
S
L
T
4
O
S
L
T
3
AC Neutral
AC Line (Hot)
Chassis (Earth) Ground
8 8 5 5 - - 2 2 6 6 4 4 V V A A C C
1000W max.
1200W max.
9 9 0 0 - - 2 2 6 6 4 4 V V A A C C
750W max.
Input AC OK - "Emitter"
Input AC OK - "Collector"
Global DC OK - "Emitter"
Global DC OK - "Collector"
External Sync
Gobal Inhibit / Optional Enable Logic "0"
Gobal Inhibit / Optional Enable Logic "1"
Gobal Inhibit / Optional Enable Return
+5VSB Housekeeping
+5VSB Housekeeping Return
5VCC External Bus
Serial Data Signal
Secondary Return
Serial Clock Signal
Address Bit 2
Address Bit 1
Address Bit 0
No connection
O
2
S
L
T
I I n n p p u u t t
I I n n p p u u t t
O
1
S
L
T
1 1 8 8 0 0 - - 2 2 6 6 4 4 V V A A C C
1200W max.
1500W max.
1 1 8 8 0 0 - - 2 2 6 6 4 4 V V A A C C
1100W max.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2006 Emerson Electric Co.
Astec Power
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Technical Support: +1 888 41 ASTEC
or +1 407 241 2752
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Units 2111-2116, Level 21
Tower 1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: +852 2437 9662
Facsimile: +852 2402 4426
For global contact, visit:
www.astecpower.com
technicalsupport@astec.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Astec
Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Printed in US A
01.06
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Embedded Power for
Business-Critical Continuity
Rev. 1.30.06
iMP Series
8 of 8