EDS10-17E FUJI [Fuji Electric], EDS10-17E Datasheet

no-image

EDS10-17E

Manufacturer Part Number
EDS10-17E
Description
FC SERIES ELECTRONIC INTEGRATOR
Manufacturer
FUJI [Fuji Electric]
Datasheet
and performs 6-digit LED's integration display. The instru-
ment offers high reliability since it has no moving parts.
FEATURES
1. The indicator uses large 6-digit LED's which are easy to
2. The instrument accepts either analog or pulse signal input.
3. A number of optional functions such as BCD transmission
SPECIFICATIONS
Input signal:
Accuracy:
Indication method:
Size of numerals:
Integration cutoff:
DATA SHEET
This electronic integrator receives analog or pulse signals
read.
and pulse transmission are available, so the integration
can be readily used for remote transmission or connected
with a computer.
Analog input;
Pulse input;
Analog input;
Pulse input;
Approx. 7.5mm high
No cutoff or 10% cutoff, selectable
(Cutoff function works via cutoff switch in-
side instrument.)
No-voltage NO contact or transistor open
collector connection
Decimal 6-digit LED's (No indication for
zero "0" in higher digits)
1 to 5V DC
4 to 20mA DC
Rated value 0.5% 1 digit
Cut point accuracy;
Hysteresis; 1% max.
FC SERIES
+0
–0.5
Rated value means the theoretical
value to be obtained when 100% input
is continuously applied and integrated.
% of input value full scale
Output current, 2mA max.
Voltage when ON, 0.6V or less
Voltage when OFF, 4.5V or more
Ton, Toff
1 digit
(input resistance 1M min.)
(input resistance 250 )
66.7 msec.
ELECTRONIC INTEGRATOR
Integration constants:
Reset method: Zero resetting possible with reset push-but-
Power supply: 24V (20 to 30V) DC (or 100V 10% AC,
Power consumption:
Power indicator lamp:
Ambient temperature:
Analog input
Pulse input
ton switch inside instrument. For model
with function for BCD transmission of inte-
grated value, resetting is possible via signal
from outside.
50/60Hz is available on request)
Approx. 6W at 24V DC, approx. 8VA at
100V AC
LED (rectangular type, green)
0 to 50 C (-30 to +70 C for storage)
(An optical integer from 20 to 9999 can be
used as a constant when so specified.)
1-hour integration vale with 100% input
Input pulses integrated on 1 : 1 base
Standard integration constants are;
1200, 1500, 1600, 1800, 2000, 3000
4000, 6000, 8000
500,
50,
100,
600,
200,
750,
250,
800,
Date
EDS10-17e
300,
900, 1000
PKH
Jan. 6, 2006
400

Related parts for EDS10-17E

EDS10-17E Summary of contents

Page 1

... LED (rectangular type, green) Ambient temperature (-30 to +70 C for storage) PKH Standard integration constants are; 50, 100, 200, 250, 300, 400 500, 600, 750, 800, 900, 1000 1200, 1500, 1600, 1800, 2000, 3000 4000, 6000, 8000 EDS10-17e Date Jan. 6, 2006 ...

Page 2

PKH Ambient humidity: 90%RH or less Outline dimensions (HxWxD): 144 400mm(case) + terminal section Mass (weight): Approx. 4.5kg Finish color: Munsell 7Y 7.3/1.4; frame color of N1.5 is available on request Mounting method: Panel flash-mount type = ...

Page 3

Output rating (DATA, BUSY) o Negative logic (NPN transistor emitter (–) common, collector output) "L" equals 1.1V/lmax. or less, input current (lmax.) equal to 30mA "H" equals applied voltage +5 to 33V, leakage current less (at 33V) ...

Page 4

PKH FUNDAMENTAL PRINCIPLE DIAGRAM With analog input Interface timing Negative logic interface timing Positive logic interface timing 4 With pulse input ...

Page 5

CODE SYMBOLS Input signal A Analog input Analog input 20mA DC P Pulse input, counter works ...

Page 6

PKH OUTLINE DIAGRAM (Unit : mm) CONNECTION DIAGRAM 6 ...

Page 7

SCOPE OF DELIVERY Integrator and mounting fixtures Output connector when BCD transmission provided 7 ...

Page 8

PKH Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, ...

Related keywords