MAX1154BEUE Maxim Integrated, MAX1154BEUE Datasheet - Page 10

no-image

MAX1154BEUE

Manufacturer Part Number
MAX1154BEUE
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1154BEUE

Number Of Channels
10
Architecture
SAR
Conversion Rate
94 KSPs
Resolution
10 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
Serial
Operating Supply Voltage
4.5 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-16
Maximum Power Dissipation
696 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1154BEUE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1154BEUE+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX1154BEUE+T
Quantity:
847
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and V
Figure 1. Load Circuits for DOUT Enable Time and SCLK to
DOUT Delay Time
The MAX1153/MAX1154 are precision-monitoring inte-
grated circuit systems specifically intended for stand-
alone operation. They can monitor diverse types of
inputs, such as those from temperature sensors and
voltage signals from pressure, vibration, and accelera-
tion sensors, and digitize these input signals. The digi-
tal values are then compared to preprogrammed
thresholds and, if the thresholds are exceeded, the
processor is alerted by an interrupt signal. No interac-
tion by the CPU or microcontroller (µC) is required until
one of the programmed limits is exceeded (Figures 3
and 4).
Voltages on all the inputs are converted to 10-bit values
sequentially and stored in the current data registers.
Note that eight of these inputs are external and two are
internal. One of the internal inputs monitors the V
voltage supply, while the other monitors the internal IC
temperature. AIN0 to AIN7 can be configured as either
single ended (default) or differential. In addition, these
inputs can be configured for single-ended or differen-
tial temperature measurements. In the temperature
configuration, the device provides the proper bias nec-
essary to measure temperature with a diode-connected
transistor sensor. The user enables which inputs are
measured (both external and internal) and sets the
delay between each sequence of measurements dur-
ing the initial setup of the device.
The values stored in the current data registers are com-
pared to the user-preprogrammed values in the thresh-
old registers (upper and lower thresholds) and, if
exceeded, activate the interrupt output and generate an
10
DOUT
100μA
______________________________________________________________________________________
a) V
DGND
OL
TO V
OH
C
LOAD
Detailed Description
= 100pF
DOUT
b) HIGH-Z TO V
100μA
DGND
V
DD
OL
C
LOAD
AND V
= 100pF
OH
TO V
OL
DD
alarm condition. If desired, the device can be pro-
grammed to average the results of many measurements
before comparing to the threshold value. This reduces
the sensitivity to external noise in the measured signal.
In addition, the user can set the number of times the
threshold is exceeded (fault cycles) before generating
an interrupt. This feature reduces falsely triggered
alarms caused by undesired, random spurious impulses.
When the fault cycle criterion is exceeded, an alarm
condition is created. The device writes the fault condi-
tion into the alarm register to indicate the alarmed input
channel.
The MAX1153/MAX1154 ADCs use a fully differential
successive-approximation register (SAR) conversion
technique and an on-chip track-and-hold (T/H) block to
convert temperature and voltage signals into a 10-bit
digital result. Both single-ended and differential config-
urations are supported with a unipolar signal range for
single-ended mode and bipolar or unipolar ranges for
differential mode. Figure 5 shows the equivalent input
circuit for the MAX1153/MAX1154. Configure the input
channels according to Tables 5 and 6 (see the Input
Configuration Register section).
In single-ended mode, the positive input (IN+) is con-
nected to the selected input channel and the negative
input (IN-) is connected to GND. In differential mode,
IN+ and IN- are selected from the following pairs:
AIN0/AIN1, AIN2/AIN3, AIN4/AIN5, and AIN6/AIN7.
Once initiated, voltage conversions require 10.6µs (typ)
to complete.
Figure 2. Load Circuit for DOUT Disable Time
DOUT
100μA
a) V
DGND
OH
TO HIGH-Z
C
LOAD
= 100pF
Converter Operation
DD
DOUT
100μA
b) V
Monitor
OL
DGND
V
TO HIGH-Z
DD
C
LOAD
= 100pF

Related parts for MAX1154BEUE