MAX1154BEUE Maxim Integrated, MAX1154BEUE Datasheet - Page 25

no-image

MAX1154BEUE

Manufacturer Part Number
MAX1154BEUE
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1154BEUE

Number Of Channels
10
Architecture
SAR
Conversion Rate
94 KSPs
Resolution
10 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
Serial
Operating Supply Voltage
4.5 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-16
Maximum Power Dissipation
696 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1154BEUE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1154BEUE+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX1154BEUE+T
Quantity:
847
At power-on or after a RESET command, the channel
enable register resets to FF hex, enabling all channels:
the internal temperature sensor, the V
AIN0–AIN7.
At power-on or after a RESET command, the input con-
figuration register resets to 00 hex, configuring
AIN0–AIN7 for single-ended voltage measurement.
At power-on or after a RESET command, the alarm reg-
ister is reset to 000000 hex, indicating that no alarm
condition exists.
At power-on or after a RESET command, each chan-
nel’s current data register is reset to 200 hex.
At power-on or after a RESET command, each chan-
nel's upper threshold register is reset to 3FF hex. This
state effectively disables the upper threshold.
At power-on or after a RESET command, each chan-
nel's lower threshold register is reset to 000 hex. This
state effectively disables the lower threshold.
At power-on or after a RESET command, each chan-
nel's configuration register is reset to 000 hex, which
configures the fault bits to cause an alarm to occur on
the first overrange or underrange condition and dis-
ables averaging.
The MAX1153/MAX1154 throughput rate depends on
the number of enabled channels, their configuration
(temperature or voltage), and the reference mode.
Voltage measurements require 10.6µs (typ) to com-
plete, and temperature measurements require 46µs.
Channel pairs configured for differential measurements
count as only one for throughput computation.
The reference system takes 20µs to power up in refer-
ence mode 00 prior to each temperature measurement,
40µs to power up in reference mode 01 after each sam-
with Internal Temperature Sensor and V
Upper Threshold Register Power-Up/Reset Defaults
Lower Threshold Register Power-Up/Reset Defaults
Channel Enable Register Power-Up/Reset Defaults
Manual conversion mode
External reference for voltage measurements
Stand-Alone, 10-Channel, 10-Bit System Monitors
Current Data Register Power-Up/Reset Defaults
Alarm Register Power-Up/Reset Defaults
______________________________________________________________________________________
Computing Data Throughput
Channel Configuration Register
Input Configuration Register
Power-Up/Reset Defaults
Power-Up/Reset Defaults
DD
monitor, and
ple wait period (if sample wait time > 80µs), and no
power-up time in reference mode 10.
The sampling period is calculated as follows:
where:
t
t
t
N
t
sion time
N
t
The terms in the previous equation are determined as
shown by the number of enabled channels, the input
channel configuration (voltage vs. temperature), the
sample wait time, and the reference mode. The follow-
ing calculation shows a numeric example:
t
The MAX1153/MAX1154 use an internal clock for all
conversions. The serial interface clock does not affect
conversion time.
Performing eight single-ended remote channels tem-
perature measurements, an internal temperature mea-
surement, and an internal V
sample wait time of zero results in an average conver-
sion rate of 24ksps or 2.4ksps per channel.
Performing eight single-ended voltage measurements,
an internal temperature measurement, and an internal
V
in an average conversion rate of 70ksps or 7ksps per
channel.
sw
pu
conv[volt]
conv[temp]
wait
sw
DD
v
t
= number of temperature-configured channels
t
= number of voltage-configured channels
sw
= reference power-up time
= all channels scan sampling period
= 40µs + 8 x 10.6µs + 2 x 46µs + 395µs = 611.8µs
40µs is the time required for the reference to power-
up (reference mode = 00) every time the
MAX1153/MAX1154 come out of automatic shut-
down mode after a sample wait period.
8 x 10.6µs is the time required for seven channels
configured for voltage measurement and the V
monitor.
2 x 46µs is the time required for temperature mea-
surement (46µs for each temperature measurement
(internal or external)).
395µs is the sample wait time, set by bits B5, B6,
B7 of the setup register (see Tables 7 and 8).
= sample wait time
measurement with sample wait time of zero results
= (t
= voltage-configured channel conversion time
pu
= temperature-configured channel conver-
) + (N
v
)t
conv[volt]
+ (N
DD
DD
t
measurement with a
)t
conv[temp]
Monitor
+ t
wait
DD
25