MAX1254AEUE+ Maxim Integrated, MAX1254AEUE+ Datasheet - Page 21

no-image

MAX1254AEUE+

Manufacturer Part Number
MAX1254AEUE+
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1254AEUE+

Number Of Channels
10
Architecture
SAR
Conversion Rate
94 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Interface Type
Serial
Operating Supply Voltage
4.5 V to 5.5 V
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External
Each channel has a channel configuration register
(Table 13) defining the number of consecutive faults to
be detected before setting the alarm bits and generat-
ing an interrupt, as well as controlling the digital averag-
ing. At power-up and after a RESET command, the
register defaults to 00 hex (no averaging, alarm on first
fault).
The value stored in the fault bits (B7–B4) in the channel
configuration register sets the number of faults that
must occur for that channel before generating an inter-
rupt. Encoding of the fault bits is straight binary with
valves 0 to 15. A fault occurs in a channel when the
value in its current data register is outside the range
defined by the channel’s upper and lower threshold
registers. For example, if the number of faults set by the
fault bits is N, an interrupt is generated when the num-
ber of consecutive faults (see note below) reach (N +
1). The fault bits default to 0 hex at power-up.
Note: Consecutive faults are those happening in con-
secutive conversion scans for the same channel. If a
Table 13. Channel Configuration Register Format
Table 14. Conversion Average Encoding
with Internal Temperature Sensor and V
B7 (MSB)
Fault B3
Stand-Alone, 10-Channel, 12-Bit System Monitors
CODE
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Channel Configuration Register
______________________________________________________________________________________
Fault B2
B6
Fault B1
1, no averaging
B5
Reserved
Reserved
Reserved
Reserved
1024
2048
128
256
512
16
32
64
N
2
4
8
Fault Bits
Fault B0
B4
fault occurs and the next scan finds the input within the
normal range defined by the thresholds, the fault
counter resets. If the next counter finds the input signal
outside the opposite threshold, rather than the previous
one, the fault counter also resets. The fault counter
increments only when counting consecutive faults
exceeding the same threshold (Figure 4).
The averaging calculated by the data-acquisition algo-
rithm of the MAX1253/MAX1254 improves the input sig-
nal-to-noise ratio (SNR) by reducing the signal
bandwidth digitally. The formula below describes the
filter implemented in the MAX1253/MAX1254:
where N = number of samples indicated in Table 14.
The averaging bits (B3–B0) in the channel configuration
register can set the N factor to any value in Table 14.
The output of the filter-running algorithm is continuously
available in the current data register. The starting value
used by the algorithm is the initial state of the current
data register. The current data register is reset to mid-
scale (800 hex) at power-up or after a RESET com-
mand, but it can be loaded with a more appropriate
initial value to improve the filter settling time.
At power-up or after a RESET command, the B3–B0
bits of the channel configuration register are set to 0
hex, corresponding to a number of averaged N = 1, no
averaging. See Table 13 and the Write-Selected
Channel Configuration Registers section for program-
ming details. See Table 14 for N encoding.
As in all digital filters, truncation can be a cause of sig-
nificant errors. In the MAX1253/MAX1254, 24 bits of
precision are maintained in the digital averaging func-
tion, maintaining a worst-case truncation error of well
below an LSB. The worst-case truncation error in the
MAX1253/MAX1254 is given by the following:
where N = number of conversions averaged.
Therefore, the worst truncation error when averaging
256 samples is 0.0623 LSBs.
Ave B3
B3
worst case truncation error
current value = [(N - 1) / N] x past value +
-
Ave B2
B2
[(present value) / N]
DD
Ave B1
B1
=
4096
N
Monitor
-
1
LSBs
Averaging
B0 (LSB)
Ave B0
21