M24C64-RMN6 STMicroelectronics, M24C64-RMN6 Datasheet - Page 17

no-image

M24C64-RMN6

Manufacturer Part Number
M24C64-RMN6
Description
EEPROM 5.5V 64K (8Kx8)
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24C64-RMN6

Product Category
EEPROM
Memory Size
64 Kbit
Organization
8 K x 8
Data Retention
40 yr
Maximum Clock Frequency
0.4 MHz
Maximum Operating Current
0.8 mA
Operating Supply Voltage
1.8 V, 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SO-8
Access Time
900 ns
Interface Type
I2C
Minimum Operating Temperature
- 40 C
Factory Pack Quantity
100
Supply Voltage - Max
5.5 V
Supply Voltage - Min
1.8 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24C64-RMN6P
Manufacturer:
ST
0
Part Number:
M24C64-RMN6T
Manufacturer:
ST
0
Part Number:
M24C64-RMN6TP
Manufacturer:
STMicroelectronics
Quantity:
3 500
Part Number:
M24C64-RMN6TP
Manufacturer:
ST
0
Part Number:
M24C64-RMN6TP
Manufacturer:
ST
Quantity:
256
Part Number:
M24C64-RMN6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24C64-RMN6TP
0
Company:
Part Number:
M24C64-RMN6TP
Quantity:
10 000
Company:
Part Number:
M24C64-RMN6TP
Quantity:
25 000
Part Number:
M24C64-RMN6TP.
Manufacturer:
ST
0
Part Number:
M24C64-RMN6TPCSA
Manufacturer:
STM
Quantity:
251
Part Number:
M24C64-RMN6TR
Manufacturer:
MIT
Quantity:
514
Part Number:
M24C64-RMN6TR
Manufacturer:
ST
0
M24C64-W M24C64-R M24C64-F M24C64-DF
5.1.3
5.1.4
Write Identification Page (M24C64-D only)
The Identification Page (32 bytes) is an additional page which can be written and (later)
permanently locked in Read-only mode. It is written by issuing the Write Identification Page
instruction. This instruction uses the same protocol and format as Page Write (into memory
array), except for the following differences:
If the Identification page is locked, the data bytes transferred during the Write Identification
Page instruction are not acknowledged (NoAck).
Lock Identification Page (M24C64-D only)
The Lock Identification Page instruction (Lock ID) permanently locks the Identification page
in Read-only mode. The Lock ID instruction is similar to Byte Write (into memory array) with
the following specific conditions:
Device type identifier = 1011b
MSB address bits A15/A5 are don't care except for address bit A10 which must be ‘0’.
LSB address bits A4/A0 define the byte address inside the Identification page.
Device type identifier = 1011b
Address bit A10 must be ‘1’; all other address bits are don't care
The data byte must be equal to the binary value xxxx xx1x, where x is don't care
Doc ID 16891 Rev 27
Instructions
17/42

Related parts for M24C64-RMN6