MC35XS3500DHFKR2 Freescale Semiconductor, MC35XS3500DHFKR2 Datasheet - Page 34

no-image

MC35XS3500DHFKR2

Manufacturer Part Number
MC35XS3500DHFKR2
Description
Power Switch ICs - Power Distribution PENTA 35MOHM ESWITCH
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC35XS3500DHFKR2

Rohs
yes
Number Of Outputs
5
On Resistance (max)
35 mOhms
Operating Supply Voltage
7 V to 20 V
Supply Current (max)
10 mA
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
PQFN-24
Minimum Operating Temperature
- 40 C
Output Current
65 mA
34
35XS3500
FUNCTIONAL DEVICE OPERATION
LOGIC COMMANDS AND REGISTERS
For OCHI1:
• if the device was in Normal mode: the output
• if the device was in Fail mode, the failure is locked until
For OCHI2 and OCLO:
• if the device was in Normal mode: the output
• if the device was in Fail mode, autorestart is activated.
corresponding register (bit D7) must be rewritten D7=1.
Application of complete OCHI window depends on
toggling or not toggling D7 bit.
restart of the device: wake-up from Sleep mode or
V
corresponding register (bit D7) must be rewritten D7=1.
Application of complete OCHI window depends on
toggling or not toggling D7 bit.
The device autorestart feature provides a fixed duty
cycle and fixed period with OCHI1 window.
autorestart feature resets OCHI2 or OCLO fault after
corresponding Autorestart period.
BATPOR1
.
Over-voltage detection and active clamp
order to limit the maximum drain to source voltage.
(OUT[1 to 5]) is turned off which leads to a high voltage at
VBAT, with an inductive V
voltage is limited at V
through the load. In case of open load condition, the positive
transient pulses (ISO 7637 pulse 2 and inductive battery line)
shall be handled by the application.
Normal mode and Fail mode.
The SPI fault reports are removed after a read operation:
The 35XS3500 provides an active gate clamp circuit, in
In case of overload on an output, the corresponding switch
Figures 13
- OC bit=(OCHI1) or (OCHI2) fault
- OVL bit=(OCHI1) or (OCHI2) or (OCLO) fault
and
14
BATCLAMP
describe the faults management in
Analog Integrated Circuit Device Data
BAT
line. The maximum VBAT
by active clamp circuitry
Freescale Semiconductor

Related parts for MC35XS3500DHFKR2