MAX17050EVKIT# Maxim Integrated, MAX17050EVKIT# Datasheet - Page 36

no-image

MAX17050EVKIT#

Manufacturer Part Number
MAX17050EVKIT#
Description
Power Management IC Development Tools MAX17050 Eval Kit
Manufacturer
Maxim Integrated
Type
Voltage Protectionr
Series
MAX17047, MAX17050r
Datasheet

Specifications of MAX17050EVKIT#

Rohs
yes
Product
Evaluation Kits
Tool Is For Evaluation Of
MAX17050
Input Voltage
2.5 V to 4.5 V
Interface Type
I2C
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Part # Aliases
90-BT07K#D00
For Use With
MAX17050
The Version register holds a 16-bit value that indicates
the version of the device.
register format.
While in active mode, the device periodically measures
the voltage between the V
to 4.98V range. The resulting data is placed in the V
register every 175.8ms with an LSb value of 0.625mV.
Additionally, the device maintains a record of the mini-
mum and maximum voltage measured by the device,
and an average voltage over a time period defined by
the host. Contents of the V
registers are indeterminate for the first conversion cycle
time period after device power-up. The last values of the
V
the device enters shutdown mode.
While in active mode, the device periodically measures the
voltage between the V
Maxim Integrated
Figure 48. Version Register Format (Output)
Figure 49. V
Figure 50. AverageV
CELL
and AverageV
MSb
MSb
MSb
2
2
V
12
12
15
CELL
2
2
V
11
11
14
Register Format (Output)
CELL
2
2
V
CELL
MSB—ADDRESS 09h
MSB—ADDRESS 19h
MSB—ADDRESS 21h
Voltage Measurement
BATT
10
10
13
Register Format (Output)
BATT
registers are maintained when
V
and CSP pins over a 0 to 4.98V
2
2
Figure 48
12
Version Register (21h)
9
9
V
CELL
and CSP pins over a 2.5V
CELL
V
2
2
11
8
8
and AverageV
shows the Version
Register (09h)
V
2
2
10
7
7
2
2
V
6
6
9
LSb
LSb
LSb
CELL
CELL
2
2
V
5
5
8
ModelGauge m3 Fuel Gauge
range. The resulting data is placed in the V
every 175.8ms with an LSb value of 0.625mV. Voltages
above the maximum register value are reported as the
maximum value. The lower 3 bits of the V
don’t care bits.
The AverageV
register readings over a configurable 12s to 24min time
period. See the FilterCFG register description for details on
setting the time filter. The resulting average is placed in the
AverageV
lower 3 bits of the AverageV
bits.The first V
up sets the starting point of the AverageV
that when a cell relaxation event is detected, the averag-
ing period for the AverageV
period defined by dt3:dt0 in the RelaxCFG register. The
AverageV
ing period when a charge or discharge current is detect-
ed.
MSb
MSb
UNITS: 0.625mV
MSb
UNITS: 0.625mV
2
2
V
Figure 50
4
4
7
MAX17047/MAX17050
2
2
V
CELL
CELL
3
3
6
shows the AverageV
CELL
CELL
Figure 49
register with an LSb value of 0.625mV. The
register reverts back to its normal averag-
V
2
2
LSB—ADDRESS 09h
LSB—ADDRESS 19h
LSB—ADDRESS 21h
2
2
5
AverageV
register reports an average of V
register reading after device power-
V
2
2
1
1
4
shows the V
V
2
2
CELL
CELL
0
0
3
CELL
register changes to the
CELL
V
register are don’t care
X
X
2
CELL
Register (19h)
register format.
CELL
V
X
X
CELL
1
register format.
CELL
LSb
LSb
LSb
register are
V
filter. Note
X
X
0
register
CELL
36

Related parts for MAX17050EVKIT#