IS42S32800D-75ETLI-TR ISSI, Integrated Silicon Solution Inc, IS42S32800D-75ETLI-TR Datasheet - Page 26

no-image

IS42S32800D-75ETLI-TR

Manufacturer Part Number
IS42S32800D-75ETLI-TR
Description
IC SDRAM 256MBIT 133MHZ 86TSOP
Manufacturer
ISSI, Integrated Silicon Solution Inc
Datasheet

Specifications of IS42S32800D-75ETLI-TR

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
256M (8Mx32)
Speed
133MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
86-TSOPII
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
to a bank within the SDRAM, a row in that bank must be
to determine the earliest clock edge after the ACTIVE
command on which a READ or WRITE command can be
entered. For example, a t
to 3. This is reflected in the following example, which cov-
ers any case where 2 < [t
IS42S32800D, IS45S32800D
CHIP OPERATION
BANK/ROW ACTIVATION
Before any READ or WRITE commands can be issued
“opened.” This is accomplished via the ACTIVE command,
which selects both the bank and the row to be activated
(see Activating Specific Row Within Specific Bank).
After opening a row (issuing an ACTIVE command), a READ
or WRITE command may be issued to that row, subject to
the t
the clock period and rounded up to the next whole number
125 MHz clock (8ns period) results in 2.25 clocks, rounded
procedure is used to convert other specification limits from
time units to clock cycles).
A subsequent ACTIVE command to a different row in the
same bank can only be issued after the previous active
row has been “closed” (precharged). The minimum time
interval between successive ACTIVE commands to the
same bank is defined by t
A subsequent ACTIVE command to another bank can be
issued while the first bank is being accessed, which results
in a reduction of total row-access overhead.The minimum
time interval between successive ACTIVE commands to
different banks is defined by t
EXAMPLE: MEETING T
26
rcd
specification. Minimum t
COMMAND
rcd
rc
rcd
.
RCD
specification of 18ns with a
rrd
CLK
(MIN)/t
rcd
.
(MIN) WHEN 2 < [T
should be divided by
ck
ACTIVE
] ≤ 3. (The same
T0
t
NOP
RCD
T1
RCD
ACTIVATING SPECIFIC ROW WITHIN SPE-
CIFIC BANK
(MIN)/TCK] ≤ 3
BA0, BA1
A0-A11
NOP
T2
CKE
RAS
CAS
CLK
WE
CS
HIGH
READ or
WRITE
T3
DON'T CARE
Integrated Silicon Solution, Inc. - www.issi.com
BANK ADDRESS
ROW ADDRESS
T4
12/01/09
Rev. C