MT46V16M8P-6T:DTR Micron Technology Inc, MT46V16M8P-6T:DTR Datasheet
MT46V16M8P-6T:DTR
Specifications of MT46V16M8P-6T:DTR
Related parts for MT46V16M8P-6T:DTR
MT46V16M8P-6T:DTR Summary of contents
Page 1
Double Data Rate (DDR) SDRAM MT46V32M4 – 8 Meg Banks MT46V16M8 – 4 Meg Banks MT46V8M16 – 2 Meg Banks Features • +2.5V ±0.2V ...
Page 2
Table 2: Addressing Parameter Configuration Refresh count Row address Bank address Column address Table 3: Speed Grade Compatibility Marking PC3200 (3-3-3) PC2700 (2.5-3-3) PC2100 (2-2-2) PC2100 (2-3-3) PC2100 (2.5-3-3) PC1600 (2-2-2) Yes -5B – -6T – -75E – -75Z – ...
Page 3
Table of Contents State Diagram ...
Page 4
State Diagram Figure 2: Simplified State Diagram Power applied Note: This diagram represents operations within a single bank only and does not capture concur- rent operations in other banks. PDF: 09005aef816fd013/Source: 09005aef82a95a3a DDR_x4x8x16_Core1.fm - 128Mb DDR: Rev. F; Core DDR: ...
Page 5
... A bidirectional data strobe (DQS) is transmitted externally, along with data, for use in data capture at the receiver. DQS is a strobe transmitted by the DDR SDRAM during READs and by the memory controller during WRITEs. DQS is edge-aligned with data for READs and center-aligned with data for WRITEs. The x16 offering has two data strobes, one for the lower byte and one for the upper byte. The DDR SDRAM operates from a differential clock (CK and CK#) ...
Page 6
... Functional Block Diagrams The 128Mb DDR SDRAM is a high-speed CMOS, dynamic random-access memory containing 134,217,728 bits internally configured as a 4-bank DRAM. Figure 3: 32 Meg x 4 Functional Block Diagram CKE CK# CK CONTROL CS# LOGIC WE# CAS# RAS# REFRESH COUNTER MODE REGISTERS 14 12 A0–A11, ADDRESS ...
Page 7
... DQS GENERATOR COL0 INPUT 16 REGISTERS 1 1 MASK 1 1 WRITE 2 16 FIFO & DRIVERS DATA In Out CK COL0 BANK3 BANK2 BANK1 BANK0 MEMORY ARRAY DATA READ MUX LATCH 16 2 DQS 8192 GENERATOR COL0 INPUT 32 REGISTERS 2 2 MASK WRITE 256 FIFO & (x32 DRIVERS ...
Page 8
Pin Assignments and Descriptions Figure 6: 66-Pin TSOP Pin Assignment (Top View DQ0 DQ1 ...
Page 9
... Address inputs: Provide the row address for ACTIVE commands, and the column address and auto precharge bit (A10) for READ/WRITE commands, to select one location out of the memory array in the respective bank. A10 sampled during a PRECHARGE command determines whether the PRECHARGE applies to one bank (A10 LOW, bank selected by BA0, BA1) or all banks (A10 HIGH) ...
Page 10
Table 4: Pin Descriptions (continued) TSOP Numbers Symbol 34, 48 12, 52, 58 REF 14, 17, 25, 42, NC 43, 53 14, 16, 17, 20, NC 25, 42, 43, 53 ...
Page 11
Package Dimensions Figure 7: 66-Pin Plastic TSOP (400 mil) 22.22 ± 0.08 0.65 TYP 0.32 ± .075 TYP PIN #1 ID Notes: 1. All dimensions are in millimeters. 2. Package width and length do not include mold protrusion; allowable mold ...
Page 12
Electrical Specifications – I Table 6: I Specifications and Conditions (x4, x8; -5B, -6T, -75E, -75Z, -75 +2.6V ±0.1V 0°C ≤ T ≤ +70°C; Notes: 1–5, 11, 13, 15, 47; Notes appear on pages ...
Page 13
Table 7: I Specifications and Conditions (x16; -5B, -6T, -75E -75Z -75 +2.6V ±0.1V 0°C ≤ T ≤ +70°C; Notes: 1–5, 11, 13, 15, 47; Notes appear on pages 26–31; See also Table 8 ...
Page 14
Table 8: I Test Cycle Times DD Values reflect number of clock cycles for each test Speed Clock Cycle I Test Grade Time –75/75Z 7.5ns DD –75E 7.5ns –6T 6ns –5B 5ns 1 I –75 7.5ns DD ...
Page 15
Electrical Specifications – DC and AC Stresses greater than those listed in Table 9 may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above ...
Page 16
Table 11: DC Electrical Characteristics and Operating Conditions (-6, -6T, -75E, -75Z, -75) Notes: 1–5, 17 apply to entire table; Notes appear on pages 26–32; V Parameter/Condition Supply voltage I/O supply voltage I/O reference voltage I/O termination voltage (system) Input ...
Page 17
Figure 8: Input Voltage Waveform Transmitter Notes Numbers in diagram reflect nominal values utilizing circuit below for all devices other than -5B. PDF: 09005aef816fd013/Source: 09005aef82a95a3a DDR_x4x8x16_Core2.fm - 128Mb DDR: Rev. F; Core DDR: ...
Page 18
Table 13: Clock Input Operating Conditions 0°C ≤ T ≤ +70° +2.6V ±0.1V Notes: 1–5, 16, 17, 31 apply to entire table; Notes appear on pages 26–32 Parameter/Condition Clock input mid-point voltage: ...
Page 19
Table 14: Capacitance (x4, x8 TSOP – 128Mb, 256Mb, 512Mb, 1Gb) Note: 14 applies to entire table; Notes appear on pages 26–32 Parameter Delta input/output capacitance: DQ0–DQ3 (x4), DQ0–DQ7 (x8) Delta input capacitance: Command and address Delta input capacitance: CK, ...
Page 20
Table 18: Electrical Characteristics & Recommended AC Operating Conditions (-5B) Notes: 1–6, 15–18, 34 apply to entire table; Notes appear on pages 26–32; 0°C ≤ T ≤ +70° Characteristics Parameter Access window of DQ from CK/CK# ...
Page 21
Table 18: Electrical Characteristics & Recommended AC Operating Conditions (-5B) (continued) Notes: 1–6, 15–18, 34 apply to entire table; Notes appear on pages 26–32; 0°C ≤ T ≤ +70° Characteristics Parameter DQS write preamble setup time ...
Page 22
Table 19: Electrical Characteristics and Recommended AC Operating Conditions (-6, -6T, -75E) Notes: 1–6, 15–18, 34 apply to entire table; Notes appear on pages 26–32; 0°C ≤ T ≤ +70° Characteristics Parameter Access window of DQ ...
Page 23
Table 19: Electrical Characteristics and Recommended AC Operating Conditions (-6, -6T, -75E) (continued) Notes: 1–6, 15–18, 34 apply to entire table; Notes appear on pages 26–32; AC Characteristics Parameter DQS read postamble ACTIVE bank a to ACTIVE bank b command ...
Page 24
Table 20: Electrical Characteristics and Recommended AC Operating Conditions (-75Z, -75) Notes: 1–6, 15–18, 34 apply to entire table; Notes appear on pages 26–32; 0°C ≤ T ≤ +70° Characteristics Parameter Access window of DQ from ...
Page 25
Table 20: Electrical Characteristics and Recommended AC Operating Conditions (-75Z, -75) (continued) Notes: 1–6, 15–18, 34 apply to entire table; Notes appear on pages 26–32; AC Characteristics Parameter PRECHARGE command period DQS read preamble DQS read postamble ACTIVE bank a ...
Page 26
Notes 1. All voltages referenced Tests for AC timing nominal reference/supply voltage levels, but the related specifications and the device operation are guaranteed for the full voltage range specified. 3. Outputs (except for I Output ...
Page 27
The CK/CK# input reference level (for timing referenced to CK/CK#) is the point at which CK and CK# cross; the input reference level for signals other than CK/CK REF 17. Inputs are not recognized as valid until ...
Page 28
CK and CK# input slew rate must be ≥1 V/ns (≥2 V/ns if measured differentially). Figure 10: Derating Data Valid Window ( 3.0ns 2.5ns 2.0ns 1.5ns 1.0ns 32. DQ and DM input slew rates must not deviate from DQS ...
Page 29
The driver pull-up current variation within nominal limits of voltage and temper- 38e. The full ratio variation of MAX to MIN pull-up and pull-down current should be 38f. The full ratio variation of the nominal pull-up to pull-down current ...
Page 30
The driver pull-up current variation, within nominal voltage and temperature 39e. The full ratio variation of the MAX-to-MIN pull-up and pull-down current should 39f. The full ratio variation of the nominal pull-up to pull-down current should be Figure 13: ...
Page 31
RPST end point and but specify when the device output is no longer driving ( t ( RPRE). 45. During initialization, V Alternatively, V provided a minimum of 42Ω of series resistance is used between the V the ...
Page 32
Table 23: Normal Output Drive Characteristics Characteristics are specified under best, worst, and nominal process variation/conditions Pull-Down Current (mA) Voltage Nominal Nominal (V) Low High 0.1 6.0 6.8 0.2 12.2 13.5 0.3 18.1 20.1 0.4 24.1 26.6 0.5 29.8 33.0 ...
Page 33
Table 24: Reduced Output Drive Characteristics Characteristics are specified under best, worst, and nominal process variation/conditions Pull-Down Current (mA) Voltage Nominal Nominal (V) Low High 0.1 3.4 3.8 0.2 6.9 7.6 0.3 10.3 11.4 0.4 13.6 15.1 0.5 16.9 18.7 ...
Page 34
Commands Tables 25 and 26 provide a quick reference of available commands. Two additional Truth Tables—Table 27 on page 35, and Table 28 on page 36— provide current state/next state information. Table 25: Truth Table 1 – Commands CKE is ...
Page 35
Table 27: Truth Table 3 – Current State Bank n – Command to Bank n Notes: 1–6 apply to entire table; Notes appear below Current State CS# RAS# CAS Any Idle ...
Page 36
Refreshing: Starts with registration of an AUTO REFRESH command and ends when • Accessing mode register: Starts with registration of a LOAD MODE REGISTER command • Precharging all: Starts with registration of a PRECHARGE ALL command and ends when ...
Page 37
This table describes alternate bank operation, except where noted (i.e., the current state is for bank n, and the commands shown are those allowed to be issued to bank m, assuming that bank such a state ...
Page 38
A WRITE command may be applied after the completion of the READ burst; otherwise, a BURST TERMINATE must be used to end the READ burst prior to asserting a WRITE com- mand. Table 30: Truth Table 5 – CKE ...
Page 39
ACTIVE (ACT) The ACTIVE command is used to open (or activate) a row in a particular bank for a subsequent access, like a read or a write, as shown in Figure 15. The value on the BA0, BA1 inputs selects ...
Page 40
Figure 16: READ Command CK# CK CKE CS# RAS# CAS# WE# ADDRESS A10 BA0, BA1 Note enable auto precharge; DIS AP = disable auto precharge. WRITE The WRITE command is used to initiate a burst write access ...
Page 41
PRECHARGE (PRE) The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks as shown in Figure 18. The value on the BA0, BA1 inputs selects the bank, and the ...
Page 42
Operations INITIALIZATION Prior to normal operation, DDR SDRAMs must be powered up and initialized in a predefined manner. Operational procedures, other than those specified, may result in undefined operation. To ensure device operation, the DRAM must be initialized as described ...
Page 43
Figure 19: INITIALIZATION Flow Diagram Step PDF: 09005aef816fd013/Source: 09005aef82a95a3a DDR_x4x8x16_Core2.fm - 128Mb DDR: Rev. F; Core DDR: Rev. A ...
Page 44
Figure 20: INITIALIZATION Timing Diagram ( ( ) ) VTD REF ) ) CK ...
Page 45
... A8, which is self- clearing). Reprogramming the mode register will not alter the contents of the memory, provided it is performed correctly. The mode register must be loaded (reloaded) when all banks are idle and no bursts are in progress, and the controller must wait the specified time before initiating the subsequent operation ...
Page 46
Burst Length (BL) Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable for both READ and WRITE bursts, as shown in Figure 21 on page 45. The burst length determines the maximum ...
Page 47
CAS Latency (CL) The CL is the delay, in clock cycles, between the registration of a READ command and the availability of the first bit of output data. The latency can be set (-5B only) ...
Page 48
Table 32: CAS Latency Speed 75 ≤ f ≤ 133 -5B 75 ≤ f ≤ 133 -6/-6T 75 ≤ f ≤ 133 -75E 75 ≤ f ≤ 133 -75Z 75 ≤ f ≤ 100 -75 Operating Mode The normal operating ...
Page 49
Figure 23: Extended Mode Register Definition Mn Notes the most significant row address bit from Table 2 on page 2. 2. The reduced drive strength option is available only on the x16 version. ...
Page 50
Figure 24: Example: Meeting T0 T1 CK# CK COMMAND ACT NOP ADDRESS Row BA0, BA1 Bank x READ During the READ command, the value on input A10 determines whether or not auto precharge is used. If auto precharge is selected, ...
Page 51
Data from any READ burst may be truncated with a BURST TERMINATE command, as shown in Figure 29 on page 56. The BURST TERMINATE latency is equal to the CL, that is, the BURST TERMINATE command should be issued x ...
Page 52
Figure 25: READ Burst CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ Notes data-out from column Three subsequent elements of ...
Page 53
Figure 26: Consecutive READ Bursts CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ Notes ( data-out from column n (or column b ...
Page 54
Figure 27: Nonconsecutive READ Bursts T0 CK# CK COMMAND READ Bank, ADDRESS Col n DQS DQ T0 CK# CK COMMAND READ Bank, ADDRESS Col n DQS DQ T0 CK# CK COMMAND READ Bank, ADDRESS Col n DQS DQ Notes: 1. ...
Page 55
Figure 28: Random READ Accesses CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ Notes ( data-out from column n (or column ...
Page 56
Figure 29: Terminating a READ Burst CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ Notes: 1. Page remains open data-out from column ...
Page 57
Figure 30: READ-to-WRITE CK# CK COMMAND ADDRESS DQS DQ DM CK# CK COMMAND ADDRESS DQS DQ DM CK# CK COMMAND ADDRESS DQS DQ DM Notes: 1. Page remains open data-out from column ...
Page 58
Figure 31: READ-to-PRECHARGE CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ CK# CK COMMAND ADDRESS DQS DQ Notes: 1. Provided precharge to be performed at x number of clock cycles after the READ command, where x ...
Page 59
Figure 32: Bank READ – Without Auto Precharge CKE NOP ACT COMMAND t IS ADDRESS Row A10 Row t IS BA0, BA1 Bank ...
Page 60
Figure 33: x4, x8 Data Output Timing – DQ (first data no longer valid) DQ (first data no longer valid) All DQ and DQS, collectively 6 t Notes the lesser DQSQ is derived at ...
Page 61
Figure 34: x16 Data Output Timing – DQ (last data valid (first data no longer valid (last data valid (first data no longer valid) 4 DQ0–DQ7 and LDQS, collectively 6 DQ (last data valid) ...
Page 62
... WRITE burst (after selected, the row will remain open for subsequent accesses. Input data appearing on the DQ is written to the memory array subject to the DM input logic level appearing coincident with the data given DM signal is registered LOW, the corresponding data will be written to memory. If the DM signal is registered HIGH, the corresponding data inputs will be ignored, and a WRITE will not be executed to that byte/column location ...
Page 63
Figure 36 on page 64 shows the nominal case and the extremes of t DQSS for Upon completion of a burst, assuming no other commands have been initiated, the DQ will remain High-Z and ...
Page 64
Figure 36: WRITE Burst COMMAND ADDRESS t DQSS (NOM) t DQSS (MIN) t DQSS (MAX) Notes data-in for column b. 2. Three subsequent elements of data-in are applied in the programmed order following ...
Page 65
Figure 37: Consecutive WRITE-to-WRITE CK# CK COMMAND ADDRESS t DQSS (NOM) DQS DQ DM Notes ( data-in from column b (or column n). 2. Three subsequent elements of data-in are applied in the programmed order ...
Page 66
Figure 38: Nonconsecutive WRITE-to-WRITE CK# COMMAND ADDRESS t DQSS (NOM) DQS DQ DM Notes ( data-in from column b (or column n). 2. Three subsequent elements of data-in are applied in the programmed order following ...
Page 67
Figure 40: WRITE-to-READ – Uninterrupting T0 CK# CK COMMAND WRITE Bank a, ADDRESS Col DQSS (NOM) DQSS DQS DQSS (MIN) DQSS DQS DQSS (MAX) DQSS DQS DQ DM Notes: ...
Page 68
Figure 41: WRITE-to-READ – Interrupting T0 CK# CK COMMAND WRITE Bank a, ADDRESS Col DQSS (NOM) DQSS DQS DQSS (MIN) DQSS DQS DQSS (MAX) DQSS DQS DQ DM Notes: ...
Page 69
Figure 42: WRITE-to-READ – Odd Number of Data, Interrupting T0 CK# CK COMMAND WRITE Bank a, ADDRESS Col DQSS (NOM) DQSS DQS DQSS (MIN) DQSS DQS DQSS (MAX) DQSS ...
Page 70
Figure 43: WRITE-to-PRECHARGE – Uninterrupting T0 CK# CK COMMAND WRITE Bank a, ADDRESS Col DQSS (NOM) DQSS DQS DQSS (MIN) DQSS DQS DQSS (MAX) DQSS DQS DQ DM Notes: ...
Page 71
Figure 44: WRITE-to-PRECHARGE – Interrupting T0 CK# CK COMMAND WRITE Bank a, ADDRESS Col DQSS (NOM) DQSS DQS DQSS (MIN) DQSS DQS DQSS (MAX) DQSS DQS DQ DM Notes: ...
Page 72
Figure 45: WRITE-to-PRECHARGE – Odd Number of Data, Interrupting T0 CK# CK COMMAND WRITE Bank a, ADDRESS Col DQSS (NOM) DQSS DQS DQSS (MIN) DQSS DQS DQSS (MAX) DQSS ...
Page 73
Figure 46: Bank WRITE – Without Auto Precharge CKE NOP 1 COMMAND ACT Row ADDRESS A10 Row BA0, ...
Page 74
Figure 47: WRITE – DM Operation CKE COMMAND NOP ACT ADDRESS Row A10 Row BA0, BA1 Bank ...
Page 75
Figure 48: Data Input Timing CK# CK DQS DQ DM Notes: 1. WRITE command issued at T0 DSH (MIN) generally occurs during t 3. DSS (MIN) generally occurs during 4. For x16, LDQS controls the lower byte and ...
Page 76
Figure 49: Bank READ – with Auto Precharge CKE NOP ACT COMMAND ADDRESS Row A10 Row IS IH BA0, BA1 Bank x DM ...
Page 77
Figure 50: Bank WRITE – with Auto Precharge CKE COMMAND NOP ACT ADDRESS Row A10 Row BA0, ...
Page 78
Although not a JEDEC requirement, to provide for future functionality features, CKE must be active (HIGH) during the AUTO REFRESH period. The AUTO REFRESH period begins when the AUTO REFRESH command is registered and ends Figure 51: Auto Refresh Mode ...
Page 79
NOPs for 200 additional clock cycles before applying a READ. Any command other than a READ can be performed reset. NOP or DESELECT commands must be issued during the Figure 52: Self Refresh Mode 1 ...
Page 80
POWER-DOWN (CKE Not Active) Unlike SDR SDRAMs, DDR SDRAMs require CKE to be active at all times an access is in progress, from the issuing of a READ or WRITE command, until completion of the access. Thus a clock suspend ...
Page 81
Figure 53: Power-Down Mode T0 CK CKE t IS VALID 2 COMMAND t IS ADDRESS VALID DQS DQ DM Notes: 1. Once initialized this command is a PRECHARGE (or if the device is ...