M25P20-VMP6 NUMONYX, M25P20-VMP6 Datasheet - Page 28

no-image

M25P20-VMP6

Manufacturer Part Number
M25P20-VMP6
Description
IC FLASH 2MBIT 50MHZ 8VFQFPN
Manufacturer
NUMONYX
Series
Forté™r
Datasheet

Specifications of M25P20-VMP6

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
2M (256K x 8)
Speed
50MHz
Interface
SPI, 3-Wire Serial
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-VFQFN, 8-VFQFPN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-3595

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M25P20-VMP6
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M25P20-VMP6
Manufacturer:
ST
0
Part Number:
M25P20-VMP6G
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M25P20-VMP6G
Manufacturer:
ST
0
Part Number:
M25P20-VMP6G
Manufacturer:
ST
Quantity:
20 000
Part Number:
M25P20-VMP6GB
Manufacturer:
MICRON
Quantity:
5 600
Part Number:
M25P20-VMP6TG
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M25P20-VMP6TGB
Manufacturer:
PERICOM
Quantity:
7 600
Company:
Part Number:
M25P20-VMP6TGB
Quantity:
2 899
M25P20
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
Table 9. Operating Conditions
Table 10. Data Retention and Endurance
Note: 1. This is preliminary data
Table 11. Capacitance
Note: Sampled only, not 100% tested, at T
28/40
Erase/Program Cycles
Symbol
Symbol
C
V
Data Retention
C
T
OUT
CC
Parameter
IN
A
Output Capacitance (Q)
Input Capacitance (other pins)
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
Parameter
Device Grade 6
Device Grade 3
Device Grade 6
Device Grade 3
A
=25°C and a frequency of 20MHz.
Parameter
Condition
1
1
(at 85°C)
Test Condition
V
V
OUT
IN
= 0V
= 0V
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Min.
Min.
–40
–40
2.7
Min.
100 000
10 000
Max.
Max.
125
3.6
85
20
20
Max.
8
6
cycles per
sector
years
Unit
Unit
Unit
°C
V
pF
pF

Related parts for M25P20-VMP6