W19B320ABT7H Winbond Electronics, W19B320ABT7H Datasheet - Page 30

no-image

W19B320ABT7H

Manufacturer Part Number
W19B320ABT7H
Description
IC FLASH 32MBIT 70NS 48TSOP
Manufacturer
Winbond Electronics
Datasheet

Specifications of W19B320ABT7H

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
32M (4Mx8, 2Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-20°C ~ 85°C
Package / Case
48-TSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W19B320ABT7H
Manufacturer:
WINBOND
Quantity:
813
Part Number:
W19B320ABT7H
Manufacturer:
WINBOND/华邦
Quantity:
20 000
SA = Address of the sector to be verified (in AUTOSELECT mode) or erased. Address bits A20-A12 uniquely select any sector.
BA = Address of the bank that is being switched to AUTOSELECT mode, is in bypass mode, or is being erased
Notes:
7.5.5 Write Operation Status
Notes:
Standard
Suspend
Erase
Mode
Mode
1. See Bus Operations Table for details.
2. All values are in hexadecimal.
3. Except for the read cycle and the fourth cycle of the AUTOSELECT command sequence, all bus cycles are write cycles.
4. Data bits DQ15-DQ8 are don’t care in command sequences, except for RD and PD.
5. Unless otherwise noted, address bits A20-A11 are “don’t care”.
6. No unlock or command cycles required when bank is reading array data.
7. The Reset command is required to return to the read mode (or to the erase-suspend-read mode if previously in Erase
8. The fourth cycle of the AUTOSELECT command sequence is a read cycle. The system must provide the bank address
9. The data is 82h for factory locked and 02h for not factory locked.
10. The data is 00h for an unprotected sector/sector block and 01h for a protected sector/sector block.
11. The Unlock Bypass command is required prior to the Unlock Bypass Program command.
12. The Unlock Bypass Reset command is required to return to the read mode when the bank is in the unlock bypass mode.
13. The system may read and program in non-erasing sectors, or enter the AUTOSELECT mode, when in the Erase
14. The Erase Resume command is valid only during the Erase Suspend mode, and requires the bank address.
15. Command is valid when device is ready to read array data or when device is in AUTOSELECT mode.
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further
3. When reading write operation status bits, the system must always provide the bank address where the Embedded
Suspend) when a bank is in the AUTOSELECT mode, or if DQ5 goes high (while the bank is providing status
information).
to obtain the manufacturer ID, device ID, or Security Sector factory protect information. Data bits DQ15-DQ8 are don’t
care. See the AUTOSELECT Command Sequence section for more information.
Suspend mode. The Erase Suspend command is valid only during a sector erase operation, and requires the bank
address.
limits. Refer to DQ5 description section for more information.
details.
Algorithm is in progress. The device outputs array data if the system addresses a non-busy bank.
Embedded Erase Algorithm
Suspend
Erase-Suspend-Program
Erase-
STATUS
Read
Embedded Program
Algorithm
Suspended
Suspended
Non-Erase
Sector
Sector
Erase
(NOTE 2)
#DQ7
#DQ7
DQ7
Data
0
1
No toggle
Toggle
Toggle
Toggle
- 30 -
DQ6
Data
(NOTE1)
DQ5
Data
0
0
0
0
DQ3
Data
N/A
N/A
N/A
1
W19B320AT/B
(NOTE 2)
No toggle
Toggle
Toggle
DQ2
Data
N/A
RY/#BY
0
0
1
1
0