LTC4210-1IS6#TRPBF Linear Technology, LTC4210-1IS6#TRPBF Datasheet - Page 14

IC CONTROLLER HOT SWAP TSOT23-6

LTC4210-1IS6#TRPBF

Manufacturer Part Number
LTC4210-1IS6#TRPBF
Description
IC CONTROLLER HOT SWAP TSOT23-6
Manufacturer
Linear Technology
Type
Hot-Swap Controllerr
Datasheet

Specifications of LTC4210-1IS6#TRPBF

Applications
General Purpose
Internal Switch(s)
No
Voltage - Supply
2.7 V ~ 16.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-23-6 Thin, TSOT-23-6
Linear Misc Type
Positive Low Voltage
Family Name
LTC4210-1
Package Type
TSOT-23
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
16.5V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Product Height (mm)
0.9mm
Product Length (mm)
2.9mm
Mounting
Surface Mount
Pin Count
6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC4210-1IS6#TRPBFLTC4210-1IS6
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LTC4210-1IS6#TRPBFLTC4210-1IS6
Manufacturer:
LT
Quantity:
20 000
Company:
Part Number:
LTC4210-1IS6#TRPBFLTC4210-1IS6#TR
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC4210-1IS6#TRPBFLTC4210-1IS6#TRMPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC4210-1IS6#TRPBFLTC4210-1IS6#TRMPBF
Quantity:
6 000
APPLICATIO S I FOR ATIO
LTC4210-1/LTC4210-2
Autoretry After Current Fault (LTC4210-1)
Figure 8 shows the waveforms of the LTC4210-1 (autoretry
version) during a circuit breaker fault. At time point B1, the
TIMER trips the COMP2 threshold of 1.3V. The GATE pin
pulls to ground while TIMER begins a “cool-off” cycle with
a 2 A pull-down to the COMP1 threshold of 0.2V. At time
point C1, the TIMER pin pulls down with approximately a
7k resistor to ground and a GATE start-up cycle is initiated.
If the fault persists, the fault autoretry duty cycle is
approximately 3.8%. Pulling the ON pin low for more than
30 s will stop the autoretry function and put the LTC4210
in reset mode.
14
V
V
TIMER
I
V
LOAD
GATE
OUT
Figure 8. Automatic Retry After Overcurrent Fault
REGULATING AT 50mV/R
NORMAL
MODE
60 A
A1
FAULT
CB
B1
U
COOL OFF
CYCLE
100 A
SENSE
2 A
U
C1
60 A
A2 B2
FAULT
CB
W
COOL OFF
CYCLE
2 A
4210 F08
U
COMP2
COMP1
Latch-Off After Current Fault (LTC4210-2)
Figure 9 shows the waveforms of the LTC4210-2 (latch-off
version) during a circuit breaker fault. At time point B, the
TIMER trips the COMP2 threshold. The GATE pin pulls to
ground while the TIMER pin is latched high by a 5 A pull-
up. The TIMER pin eventually reaches the soft-clamped
voltage (V
user can either pull the TIMER pin to below 0.2V externally
or cycle the ON pin low for more than 30 s.
V
V
TIMER
I
V
LOAD
CLAMP
GATE
Figure 9. Latchoff After Overcurrent Fault
OUT
REGULATING AT 50mV/R
NORMAL
MODE
) of 2.3V. To clear the latchoff mode, the
60 A
FAULT
A
CB
B
LATCHED OFF CYCLE
C
SENSE
2410 F09
V
COMP2
COMP1
0V
0V
CLAMP
421012f