Specifications of LT4256-3CGN

Applications
General Purpose
Internal Switch(s)
No
Voltage - Supply
10.8 V ~ 80 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
16-SSOP (0.150", 3.90mm Width)
Family Name
LT4256-3
Package Type
SSOP N
Operating Supply Voltage (min)
10.8V
Operating Supply Voltage (max)
80V
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Product Depth (mm)
3.99mm
Product Height (mm)
1.5mm
Mounting
Surface Mount
Pin Count
16
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LT4256-3CGN
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT4256-3CGN
Manufacturer:
LT/凌特
Quantity:
20 000
Part Number:
LT4256-3CGN#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT4256-3CGN#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
APPLICATIO S I FOR ATIO
500mA/DIV
TIMER
TIMER provides a method for programming the maximum
time the part is allowed to operate in current limit. When
the current limit circuitry is not active, TIMER is pulled to
GND by a 3µA current source. When the current limit
circuitry becomes active, a 108µA pull-up current source
is connected to TIMER and the voltage will rise with a slope
equal to 105µA/C
Once the desired maximum current limit time is known,
the capacitor value is:
Whenever TIMER reaches 4.65V (typ), the internal fault
latch is set causing GATE to be pulled low and TIMER to be
discharged to GND by the 3µA current source. The part is
not allowed to turn on again until the voltage on TIMER
falls below 0.65V (typ).
Whenever GATE is commanded off by any fault condition,
it is discharged with a high current, turning off the external
MOSFET. The waveform in Figure 10 shows how the
output latches off following a current fault. The drop
50V/DIV
50V/DIV
5V/DIV
TIMER
C nF
GATE
V
I
[ ]
OUT
OUT
=
25 • t ms ; C =
Figure 10. Latch Off Waveforms
[ ]
TIMER
U
as long as the circuitry stays active.
10ms/DIV
U
105 A
4.65V
µ
• t
W
4256 F10
U
(6)
500mA/DIV
across the sense resistor is held at 55mV as the timer
ramps up. Once TIMER reaches its shutdown threshold
(4.65V typically), the circuit latches off.
Automatic Restart
If RETRY is floating, then the device automatically restarts
after a current overload fault.
When the voltage at TIMER ramps back down to 0.65V
(typ), the LT4256-3 turns on again. If the short-circuit
condition at the output still exists, the cycle will repeat
itself indefinitely. The duty cycle under short-circuit con-
ditions is 3% which prevents Q1 from overheating. Fig-
ure 11 shows representative waveforms during a short
circuit.
Latch Off Operation
If RETRY is grounded, the LT4256-3 will latch off after a
current fault. After the part latches off, it may be com-
manded to start back up. This is accomplished by cycling
UV to ground and then back high (this command can only
be accepted after TIMER discharges below the 0.65V typ
threshold, which prevents overheating transistor Q1).
50V/DIV
50V/DIV
5V/DIV
TIMER
GATE
V
I
OUT
OUT
Figure 11. RETRY Waveforms