LED7707TR STMicroelectronics, LED7707TR Datasheet - Page 21

IC LED DRIVR WHT BCKLT 24-VFQFPN

LED7707TR

Manufacturer Part Number
LED7707TR
Description
IC LED DRIVR WHT BCKLT 24-VFQFPN
Manufacturer
STMicroelectronics
Type
Backlight, White LEDr
Datasheet

Specifications of LED7707TR

Topology
PWM, Step-Up (Boost)
Number Of Outputs
6
Internal Driver
Yes
Type - Primary
Backlight
Type - Secondary
White LED
Frequency
250kHz ~ 1MHz
Voltage - Supply
4.5 V ~ 36 V
Voltage - Output
36V
Mounting Type
Surface Mount
Package / Case
24-VFQFN, 24-VFQFPN
Operating Temperature
0°C ~ 85°C
Current - Output / Channel
85mA
Internal Switch(s)
Yes
High Level Output Current
85 mA
Operating Supply Voltage
4.5 V to 36 V
Maximum Supply Current
1 mA
Maximum Power Dissipation
2.3 W
Maximum Operating Temperature
+ 150 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
For Use With
497-10044 - BOARD EVAL LCD BACKLIGHT LED7707
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Efficiency
-
Lead Free Status / Rohs Status
 Details
Other names
497-8492-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LED7707TR
Manufacturer:
ST
Quantity:
12 000
Part Number:
LED7707TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
LED7707TR
Manufacturer:
ST
0
LED7707
5.2.2
5.3
PWM dimming
The brightness control of the LEDs is performed by a pulse-width modulation of the rows
current. When a PWM signal is applied to the DIM pin, the current generators are turned on
and off mirroring the DIM pin behavior. Actually, the minimum dimming duty-cycle depends
on the dimming frequency.
The real limit to the PWM dimming is the minimum on-time that can be managed for the
current generators; this minimum on-time is approximately 10 μs.
Thus, the minimum dimming duty-cycle depends on the dimming frequency according to the
following formula:
Equation 10
For example, at a dimming frequency of 1 kHz, 1% of dimming duty-cycle can be managed.
During the off-phase of the PWM signal the boost converter is paused and the current
generators are turned off. The output voltage can be considered almost constant because of
the relatively slow discharge of the output capacitor. During the start-up sequence (see
Section 5.1.3 on page 13
regardless of the applied dimming signal.
Figure 15. PWM dimming waveforms
Fault management
The main loop keeps the row having the lowest voltage drop regulated to about 700 mV.
This value slightly depends on the voltage across the remaining active rows. After the soft-
start sequence, all protections turn active and the voltage across the active current
generators is monitored to detect shorted LEDs.
 
) the dimming duty-cycle is forced to 100% to detect floating rows
D
DIM
,
min
=
10
μ
s
f
DIM
Operation description
10µs minimum on-time
10µs minimum on-time
21/47