MAX6699EE99+ Maxim Integrated Products, MAX6699EE99+ Datasheet - Page 7

IC TEMP MONITOR 5CH 16-QSOP

MAX6699EE99+

Manufacturer Part Number
MAX6699EE99+
Description
IC TEMP MONITOR 5CH 16-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6699EE99+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 1. Internal Block Diagram
From a software perspective, the MAX6699 appears as
a series of 8-bit registers that contain temperature-mea-
surement data, alarm threshold values, and control bits.
A standard SMBus-compatible 2-wire serial interface is
used to read temperature data and write control bits
and alarm threshold data. The same SMBus slave
address also provides access to all functions.
The MAX6699 employs four standard SMBus protocols:
write byte, read byte, send byte, and receive byte
(Figure 2). The shorter receive-byte protocol allows
quicker transfers, provided that the correct data regis-
ter was previously selected by a read byte instruction.
Use caution with the shorter protocols in multimaster
5-Channel Precision Temperature Monitor
DXP1
DXN1
DXP2
DXN2
DXP3
DXN3
DXP4
DXN4
_______________________________________________________________________________________
SMBus Digital Interface
10/100µA
BUFFER
INPUT
V
CC
REF
SCL
INTERFACE
SMBus
ADC
systems, since a second master could overwrite the
command byte without informing the first master. Figure
3 is the SMBus write timing diagram, and Figure 4 is
the SMBus read timing diagram.
The remote diode 1 measurement channel provides 11
bits of data (1 LSB = 0.125°C). All other temperature-
measurement channels provide 8 bits of temperature
data (1 LSB = 1°C). The 8 most significant bits (MSBs)
can be read from the local temperature and remote
temperature registers. The remaining 3 bits for remote
diode 1 can be read from the extended temperature
register. If extended resolution is desired, the extended
resolution register should be read first. This prevents
the most significant bits from being overwritten by new
COUNT
COUNTER
SDA
ALERT RESPONSE ADDRESS
REMOTE TEMPERATURES
LOCAL TEMPERATURES
ALERT THRESHOLD
OVERT THRESHOLD
COMMAND BYTE
MAX6699
REGISTER BANK
ALARM
ALU
OVERT
AVERT
7

Related parts for MAX6699EE99+