W83791G Nuvoton Technology Corporation of America, W83791G Datasheet - Page 60

no-image

W83791G

Manufacturer Part Number
W83791G
Description
IC MONITOR H/W 48-LQFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheet

Specifications of W83791G

Function
Hardware Monitor
Topology
ADC
Sensor Type
External
Sensing Temperature
External Sensor
Output Type
I²C™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83791G
Manufacturer:
NXP
Quantity:
6 000
Part Number:
W83791G
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Part Number:
W83791G
Manufacturer:
WINBOND/华邦
Quantity:
20 000
7.59 Fan 1 PWM Stop Duty Cycle Register ⎯ Index 88h (Bank 0)
Power on default: 01h
7.60 Fan 2 PWM Stop Duty Cycle Register ⎯ 89h (Bank 0)
Power on default: 01h
7.61 Fan 1 Start-up Duty Cycle Register ⎯ Index 8Ah (Bank 0)
Power on default: 01h
7.62 Fan 2 Start-up Duty Cycle Register ⎯ Index 8Bh (Bank 0)
Power on default: 01h
7.63 Fan 1 Stop Time Register ⎯ Index 8Ch (Bank 0)
Power on default: 3Ch
7-0
7-0
7-0
7-0
7-0
BIT
BIT
BIT
BIT
BIT
STOP_DC2[7:0]
START_DC1[7:0]
START_DC2[7:0]
STOP_TIME1[7:0]
STOP_DC1[7:0]
NAME
NAME
NAME
NAME
NAME
ATTRIBUTE
ATTRIBUTE
ATTRIBUTE
ATTRIBUTE
ATTRIBUTE
R/W
R/W
R/W
R/W
R/W
decreases to under this value. This register should be
written a non-zero minimum PWM stop duty cycle.
In Thermal Cruise mode, PWM duty will be 0 if it
decreases to under this value. This register should be
written a non-zero minimum PWM stop duty cycle.
In Thermal Cruise mode, PWM duty will increase from 0
to this register value to provide a minimum duty cycle to
turn on the fan. This register should be written a fan
start-up duty cycle.
In Thermal Cruise mode, PWM duty will increase from 0
to this register value to provide a minimum duty cycle to
turn on the fan. This register should be written a fan
start-up duty cycle.
In Thermal Cruise mode, this register determines the
time of which PWM duty is from stop duty cycle to 0 duty
cycle. The unit of this register is 0.1 second. The default
value is 6 seconds.
In Thermal Cruise mode, PWM duty will be 0 if it
- 54 -
Publication Release Date: April 14, 2006
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
W83791D/G
Revision 1.1