DS18B20-PAR+T&R Maxim Integrated Products, DS18B20-PAR+T&R Datasheet - Page 14

no-image

DS18B20-PAR+T&R

Manufacturer Part Number
DS18B20-PAR+T&R
Description
IC THERM MICROLAN PROG-RES TO-92
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of DS18B20-PAR+T&R

Function
Thermometer, Thermostat
Topology
Register Bank, Scratchpad
Sensor Type
Internal
Sensing Temperature
-55°C ~ 100°C
Output Type
1-Wire®
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 100°C
Mounting Type
Through Hole
Package / Case
TO-92-3 (Standard Body), TO-226
Full Temp Accuracy
+/- 2 C
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The DS18B20-PAR samples the 1-Wire bus during a window that lasts from 15 μs to 60 μs after the
master initiates the write time slot. If the bus is high during the sampling window, a 1 is written to the
DS18B20-PAR. If the line is low, a 0 is written to the DS18B20-PAR.
READ/WRITE TIME SLOT TIMING DIAGRAM Figure 13
READ TIME SLOTS
The DS18B20-PAR can only transmit data to the master when the master issues read time slots.
Therefore, the master must generate read time slots immediately after issuing a Read Scratchpad [BEh]
command, so that the DS18B20-PAR can provide the requested data. In addition, the master can generate
read time slots after issuing a Recall E
DS18B20-PAR FUNCTION COMMAND section.
All read time slots must be a minimum of 60 μs in duration with a minimum of a 1 μs recovery time
between slots. A read time slot is initiated by the master device pulling the 1-Wire bus low for a
minimum of 1 μs and then releasing the bus (see Figure 13). After the master initiates the read time slot,
the DS18B20-PAR will begin transmitting a 1 or 0 on bus. The DS18B20-PAR transmits a 1 by leaving
the bus high and transmits a 0 by pulling the bus low. When transmitting a 0, the DS18B20-PAR will
release the bus by the end of the time slot, and the bus will be pulled back to its high idle state by the
pullup resister. Output data from the DS18B20-PAR is valid for 15 μs after the falling edge that initiated
1-WIRE BUS
1-WIRE BUS
V
GND
V
GND
PU
PU
> 1 μs
OF SLOT
START
15 μs
15 μs
LINE TYPE LEGEND
MASTER WRITE “0” SLOT
MASTER READ “0” SLOT
60 μs < T
MIN
Master samples
15 μs
DS18B20-PAR samples
Bus master pulling low
Resistor pullup
X
“0” < 120
TYP
45 μs
2
[B8h] command to find out the recall status as explained in the
30 μs
MAX
14 of 19
> 1 μs
OF SLOT
START
DS18B20-PAR pulling low
15 μs
15 μs
1 μs < T
1 μs < T
MASTER WRITE “1” SLOT
> 1 μs
MASTER READ “1” SLOT
REC
REC
MIN
<
<
Master samples
15 μs
DS18B20-PAR samples
TYP
30 μs
MAX
DS18B20-PAR

Related parts for DS18B20-PAR+T&R