DS1620S Maxim Integrated Products, DS1620S Datasheet - Page 8

IC THERMOMETER/STAT DIG 8-SOIC

DS1620S

Manufacturer Part Number
DS1620S
Description
IC THERMOMETER/STAT DIG 8-SOIC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1620S

Function
Thermometer, Thermostat
Topology
Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
Digital
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (5.3mm Width), 8-SOP, 8-SOEIAJ
Full Temp Accuracy
+/- 2 C
Digital Output - Bus Interface
Serial (3-Wire)
Digital Output - Number Of Bits
9 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1620S
Manufacturer:
DALLAS
Quantity:
4 225
Part Number:
DS1620S
Manufacturer:
DALLAS
Quantity:
140
Part Number:
DS1620S
Manufacturer:
MAX
Quantity:
21
Part Number:
DS1620S
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1620S+
Manufacturer:
Maxim
Quantity:
4 127
Part Number:
DS1620S+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1620S+T
Quantity:
5 000
Part Number:
DS1620S+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1620S+T&R
Manufacturer:
MAXIM
Quantity:
414
Part Number:
DS1620S+T&R
Manufacturer:
MAXIM
Quantity:
5 000
Part Number:
DS1620S+T&R
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
DS1620S+T&R
Quantity:
2 461
Part Number:
DS1620S+TR
Manufacturer:
MAXIM
Quantity:
8 000
Part Number:
DS1620S+TR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
DS1620S+TR
Quantity:
882
DS1620 COMMAND SET Table 4
NOTES:
1. In continuous conversion mode, a Stop Convert T command will halt continuous conversion. To
2. Writing to the E
Read Temperature
INSTRUCTION
Start Convert T
Stop Convert T
Read Counter
Write Config
Read Config
restart, the Start Convert T command must be issued. In one–shot mode, a Start Convert T command
must be issued for every temperature reading desired.
writes should be requested for at least 10 ms.
Read Slope
Write TH
Write TL
Read TH
Read TL
2
requires up to 10 ms at room temperature. After issuing a write command no further
DESCRIPTION
Reads last converted temperature
value from temperature register.
Reads value of count remaining
from counter.
Reads value of the slope
accumulator.
Initiates temperature conversion.
Halts temperature conversion.
Writes high temperature limit value
into TH register.
Writes low temperature limit value
into TL register.
Reads stored value of high
temperature limit from TH register.
Reads stored value of low
temperature limit from TL register.
Writes configuration data to
configuration register.
Reads configuration data from
configuration register.
TEMPERATURE CONVERSION COMMANDS
THERMOSTAT COMMANDS
8 of 12
PROTOCOL
AAh
ACh
A0h
A9h
EEh
A1h
A2h
0Ch
22h
01h
02h
DATA AFTER
3-WIRE BUS
PROTOCOL
<write data>
<write data>
<write data>
<read data>
<read data>
<read data>
<read data>
<read data>
<read data>
ISSUING
Idle
Idle
NOTES
1
1
2
2
2
2
2
2

Related parts for DS1620S