MAX6683AUB+ Maxim Integrated Products, MAX6683AUB+ Datasheet - Page 3

IC TEMP SENSOR MON 10-UMAX

MAX6683AUB+

Manufacturer Part Number
MAX6683AUB+
Description
IC TEMP SENSOR MON 10-UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6683AUB+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
Internal
Sensing Temperature
-40°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRICAL CHARACTERISTICS (continued)
(T
Note 1: Total monitoring time includes temperature conversion and four analog input voltage conversions.
Note 2: A master device must provide at least a 300ns hold time for the SDA signal, referred to V
Note 3: C
Note 4: Input filters on SDA, SCL, and ADD suppress noise spikes <50ns.
TIMING (Figures 3 and 4)
Serial Clock Frequency
Bus Free Time Between Stop
and Start
Start Condition Hold Time
Stop Condition Hold Time
Clock Low Time
Clock High Time
Data Setup Time
Data Hold Time
Receive SCL/SDA Minimum
Rise Time
Receive SCL/SDA Maximum
Rise Time
Receive SCL/SDA Minimum Fall
Time
Receive SCL/SDA Maximum Fall
Time
Transmit SDA Fall Time
Pulse Width of Spike
Suppressed
A
= -40°C to +125°C, unless otherwise noted. Typical values are at V
undefined region of SCL’s falling edge.
b
PARAMETER
= total capacitance of one bus line in pF. Rise and fall times are measured between 0.3
_______________________________________________________________________________________
SYMBOL
t
t
HD
t
t
SU
T
HD
SU
T
T
f
HIGH
LOW
SCL
t
BUF
:
System Monitor in a 10-Pin µMAX
:
t
t
t
t
t
SP
DAT
:
DAT
R
R
:
F
F
F
STO
STA
(Note 2)
(Note 3)
(Note 3)
(Note 3)
(Note 3)
C
(Note 4)
b
= 400pF, I
SINK
CONDITIONS
Temperature Sensor and
= 3mA
CC
= +3.3V, T
A
= +25°C.)
0.1C
IL
20 +
MIN
100
1.3
0.6
0.6
1.3
0.6
of the SCL signal, to bridge the
0
0
b
V
CC
0.1C
0.1C
to 0.7
20 +
20 +
TYP
300
300
50
b
b
V
CC
MAX
400
300
0.9
.
UNITS
kHz
µs
µs
µs
µs
µs
ns
µs
ns
ns
ns
ns
ns
ns
3

Related parts for MAX6683AUB+