HCPL-T250-060E Avago Technologies US Inc., HCPL-T250-060E Datasheet
HCPL-T250-060E
Specifications of HCPL-T250-060E
Available stocks
Related parts for HCPL-T250-060E
HCPL-T250-060E Summary of contents
Page 1
... The voltage and current supplied by this optocou‑ pler makes it ideally suited for directly driving IGBTs with ratings up to 1200 V/25 A. For IGBTs with higher ratings, the HCPL‑T250 can be used to drive a discrete power stage which drives the IGBT gate. Functional Diagram ...
Page 2
... To order, choose a part number from the part number column and combine with the desired option from the op‑ tion column to form an order entry. Example 1: HCPL‑T250‑560E to order product of 300 mil DIP Gull Wing Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747‑5‑2 Safety Approval in RoHS compliant. Example 2: HCPL‑ ...
Page 3
Package Outline Drawings Standard DIP Package 9.65 ± 0.25 (0.380 ± 0.010 PIN ONE 1.19 (0.047) MAX. 3.56 ± 0.13 (0.140 ± 0.005) PIN ONE 1.080 ± 0.320 (0.043 ± 0.013) Gull Wing Surface ...
Page 4
Solder Reflow Thermal Profile 300 PREHEATING RATE 3°C + 1°C/–0.5°C/SEC. REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC. 200 160°C 150°C 140°C 3°C + 1°C/–0.5°C 100 PREHEATING TIME 150° SEC. ROOM TEMPERATURE Note: Non-halide flux should ...
Page 5
... Solder Reflow Temperature Profile Notes: 1. Maximum pulse width = 10 µs, maximum duty cycle = 0.2%. See HCPL‑3120 Applications section for additional details on limiting I 2. Derate linearly above 70°C free‑air temperature at a rate of 0.3 mA/°C. 3. Derate lineraly above 70°C free‑air temperature at a rate of 4.8 mW/°C. ...
Page 6
... Recommended Operating Conditions Parameter Symbol Power Supply Voltage V CC Input Current (ON) Input Voltage (OFF Electrical Specifications (Compared with HCPL‑3120) Over recommended operating conditions ( Ground) unless otherwise specified. EE Parameter Symbol Units Input Forward V F Voltage Temperature ∆V /∆T mV/° Coefficient of Forward Voltage ...
Page 7
... CC EE Notes: 4. The difference between t and t between any two HCPL‑3120 parts under the same test condition. PHL PLH 5. Common mode transient immunity in the high state is the maximum tolerable dV output will remain in the high state (i.e Common mode transient immunity in a low state is the maximum tolerable dV put will remain in a low state (i.e., V < ...