ACPL-4800-060E Avago Technologies US Inc., ACPL-4800-060E Datasheet - Page 5

no-image

ACPL-4800-060E

Manufacturer Part Number
ACPL-4800-060E
Description
OPTOCOUPLER IPM 5MBD VDE 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-4800-060E

Output Type
Push-Pull, Totem-Pole
Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
25mA
Data Rate
5MBd
Propagation Delay High - Low @ If
150ns @ 10mA
Current - Dc Forward (if)
10mA
Input Type
DC
Mounting Type
Through Hole
Fall Time
20 ns
Logic Gate Type
AND Schmitt
Maximum Baud Rate
5 MBps
Rise Time
16 ns
Configuration
1 Channel
Isolation Voltage
3750 Vrms
Maximum Propagation Delay Time
350 ns
Maximum Forward Diode Voltage
1.7 V
Maximum Reverse Diode Voltage
5 V
Maximum Forward Diode Current
10 mA
Maximum Continuous Output Current
25 mA
Maximum Power Dissipation
210 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Number Of Elements
1
Forward Voltage
1.7V
Forward Current
10mA
Output Current
25mA
Package Type
PDIP
Operating Temp Range
-40C to 100C
Power Dissipation
210mW
Propagation Delay Time
350ns
Pin Count
8
Mounting
Through Hole
Reverse Breakdown Voltage
5V
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-4800-060E
Manufacturer:
AVAGO
Quantity:
3 000
Part Number:
ACPL-4800-060E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option 060)
*
Note:
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
5
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap(External Clearance)
Minimum External Track-
ing (External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Input to Output Test Voltage, Method a*
V
Highest Allowable Over-voltage(Transient Over-voltage t
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power (refer to Thermal Derating Curve)
Insulation Resistance at T
IORM
IORM
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 450 V
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
x 1.875=V
x 1.5=V
PR
, Type and Sample Test, t
PR
,100% Production Test with t
S
, V
IO
Symbol
L(101)
L(102)
CTI
= 500 V
rms
rms
8-Pin DIP
7.1
7.4
0.08
NA
200
IIIa
m
=60 sec, Partial discharge < 5 pC
m
=1 sec, Partial discharge < 5 pC
Unit
mm
mm
mm
mm
ini
= 10 sec)
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance, conductor to conductor,
usually the direct distance between the photo emitter
and photo detector inside the optocoupler cavity.
Measured from input terminals to output terminals,
along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Symbol
V
V
V
V
T
I
P
PUT
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUT-
S
Characteristic
I-IV
I-III
55/85/21
2
630
1181
945
6000
175
230
600
>10
9
Unit
V
V
V
V
°C
mA
mW
W
peak
peak
peak
peak

Related parts for ACPL-4800-060E