NHD-240128WG-BFGH-VZ#-C Newhaven Display, NHD-240128WG-BFGH-VZ#-C Datasheet

LCD MOD GRAPH 240X128 WH TRANSFL

NHD-240128WG-BFGH-VZ#-C

Manufacturer Part Number
NHD-240128WG-BFGH-VZ#-C
Description
LCD MOD GRAPH 240X128 WH TRANSFL
Manufacturer
Newhaven Display
Series
NHD-240128WG-Br
Datasheet

Specifications of NHD-240128WG-BFGH-VZ#-C

Display Type
LCD - Monochrome
Display Mode
Transflective
Viewing Area
114.00mm L x 64.00mm W
Backlight
CCFL - White
Dot Size
0.43mm W x 0.43mm H
Dot Pitch
0.45mm x 0.45mm
Dot Pixels
240 x 128
Pixel Density
240 x 128
Fluid Type
STN
Module Size (w X H X T)
144 mm x 104 mm x 14.3 mm
Backlighting
CCFL White
Background Color
Gray
Operating Temperature Range
- 20 C to + 70 C
Style
LCD Graphic Display
Interface
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
 
 
NHD‐240128WG‐BFGH‐VZ#‐C 
Graphic Liquid Crystal Display Module 
 
NHD‐   
24064‐   
WG‐ 
B‐ 
F‐ 
G‐ 
H‐ 
VZ#‐ 
C‐ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Newhaven Display 
240 x 64 pixels 
Display Type: Graphic 
Model 
White CCFL Backlight 
STN‐Gray 
Transflective, 6:00 view, Wide Temperature (‐20°C ~ +70°C) 
With Built‐in Negative Voltage Supply 
Flex Cable: A9BAG‐2002F‐ND  
RoHS Compliant 
 
 
 
 
nhtech@newhavendisplay.com   
 
 
 
 
 
 
 
 
 
 
 
 
www.newhavendisplay.com 
Newhaven Display International, Inc. 
2511 Technology Drive, Suite 101 
Elgin IL, 60124 
Ph: 847‐844‐8795 
 
[1] 
nhsales@newhavendisplay.com 
Fax: 847‐844‐8796 

Related parts for NHD-240128WG-BFGH-VZ#-C

NHD-240128WG-BFGH-VZ#-C Summary of contents

Page 1

... NHD‐240128WG‐BFGH‐VZ#‐C  Graphic Liquid Crystal Display Module    NHD‐    Newhaven Display  24064‐    240 x 64 pixels  WG‐    Display Type: Graphic  B‐    ...

Page 2

Document Revision History  Revision  Date  0  11/10/2008  1  4/27/2010  2  3/3/2011                Functions and Features  • 240 x 128 pixels  • Built‐in RA6963 controller   • +5.0V Power Supply  • White CCFL Backlight  • 1/128 duty  • RoHS Compliant                ...

Page 3

... B/L LCM 152.0 0.5 144.0 0.5 128.0 114.0(VA) 107.98(AA) 240*128 DOTS 138.0 0.45 0.43 DOT SIZE 14 9.2 125.0 10 1.6 3.5 PTH CCFL B/L 7.0 PAD The non-specified tolerance of dimension is Newhaven Display NHD-240128WG-BFGH-VZ#-C 1 Vss 2 Vdd C DB0 8 DB1 9 DB2 10 DB3 11 DB4 12 DB5 ...

Page 4

Pin Description and Wiring Diagram  Pin No.  Symbol  External  Connection  1  VSS  Power Supply  2  VDD  Power Supply  3  V0  Adj. Power Supply  Power supply for contrast (approx. ‐13.0V) 4  C/D  MPU  5  /RD  MPU  6  /WR  MPU  7‐14  DB0‐DB7  MPU  15  /CE  MPU  16  /RESET  MPU  17  VEE  Power Supply  18  MD2  MPU  19  ...

Page 5

Electrical Characteristics  Item  Operating Temperature Range  Storage Temperature Range  Supply Voltage  Supply Current  Supply for LCD (contrast)  “H” Level input  “L” Level input  “H” Level output  “L” Level output    Backlight Supply Voltage  Backlight Supply Current   Backlight Lifetime        Optical Characteristics  Item  Viewing Angle ‐ Vertical (top)  Viewing Angle‐ Vertical (bottom)  Viewing Angle‐ Horizontal (left)  Viewing Angle ‐ Horizontal (right)  Contrast Ratio  Response Time (rise)  Response Time (fall)        Controller Information  Built‐in RA6963. Download specification at http://www.newhavendisplay.com/app_notes/RA6963.pdf                ...

Page 6

Table of Commands   [6]    ...

Page 7

Timing Characteristics                              [7]      ...

Page 8

Example Initialization Program    //‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐  Sub Writecom   P1 = A                                                       'move data to port 1   Set P3.0                                                     'set I/D for instruction   Reset P3.1                                                   'reset /CS   Reset P3.4                                                   'reset /WR   Set P3.1                                                     'set /CS   Set P3.4                                                     'set /WR  End Sub    Sub Writedata   P1 = A                                                       'move data to port 1   Reset P3.0                                                   'reset I/D for instruction   Reset P3.1   Reset P3.4                                                   'toggle /CS and /WR   Set P3.1   Set P3.4  End Sub    //‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐  Sub Init   Set P3.6   Set P3.7   Reset P3.3                                                   'reset FS   A = &H00   Call Writedata   Call Writedata                                               'text address = 0000h   A = &H40   Call Writecom                                                'text home address set   A = &H00   Call Writedata   A = &H40                                                     'graphic home address = 4000h   Call Writedata   A = &H42   Call Writecom                                                'graphic home address set   A = &H1E   Call Writedata   A = &H00                                                     'text area address = 001Eh  ...

Page 9

Quality Information  Test Item  High Temperature storage  storage temperature for a long time.  Low Temperature storage  Endurance test applying the low storage  temperature for a long time.  High Temperature  Endurance test applying the electric stress  Operation  (voltage & current) and the high thermal  stress for a long time.  Low Temperature  Endurance test applying the electric stress  Operation  (voltage & current) and the low thermal  stress for a long time.  High Temperature /  Endurance test applying the electric stress  Humidity Operation  (voltage & current) and the high thermal  with high humidity stress for a long time.  Thermal Shock resistance  Endurance test applying the electric stress  (voltage & current) during a cycle of low  and high thermal stress.   Vibration test  Endurance test applying vibration to  simulate transportation and use.  Static electricity test  Endurance test applying electric static  discharge.  Note 1: No condensation to be observed.  Note 2: Conducted after 4 hours of storage at 25 Note 3:  Test performed on product itself, not inside a container.  ...

Related keywords