LXMG1626-05-45 Microsemi Analog Mixed Signal Group, LXMG1626-05-45 Datasheet - Page 5

MOD INVERTER CCFL DUAL 6W 5V

LXMG1626-05-45

Manufacturer Part Number
LXMG1626-05-45
Description
MOD INVERTER CCFL DUAL 6W 5V
Manufacturer
Microsemi Analog Mixed Signal Group
Series
PanelMatch™r
Type
Inverters for CCFL and UV Lampsr
Datasheet

Specifications of LXMG1626-05-45

Voltage - Input
5.0V
Output
1500V
Size / Dimension
4.45" L x 1.18" W x 0.26" H (113mm x 30mm x 6.5mm)
Mounting Type
Chassis Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Copyright © 2007
Rev. 1.1, 2007-07-19
* Under some conditions the second lamp will also shutdown, this is especially
One Lamp High
High Side Short
Lamp(s) Status
Side Short to
Both Lamps
Both Lamps
One Lamp
Operation
to Ground
true if the inverter draws an arc going open or when shorted.
TM
Ground
Normal
0 < P . W . < 100 % of period
Open
Open
Figure 1A – PWM Brightness Control
10µs to 200µS
Figure 2 – FAULT Output Operation
500K
from System
PWM Signal
(Output current set to maximum)
DAC or
Pot
Figure 1 – Brightness Control
P.W.
BRITE
SLEEP
SET
11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570
BRITE
1
FAULT
SET
NC
SLEEP
LXMG1626-05-45
High
High
High
High
Low
FAULT
LXMG1626-05-45
FAULT
5V
V
NC
IN
`
5V
GND
V
BRITE
IN
LXMG 1626 -05-45
Normal @ ½ lamp
Normal @ ½ lamp
V
Inverter Operation
GND
V
V
Normal full lamp
HI2
HI1
LO
Shutdown
Shutdown
current*
current*
V
V
V
current
HI2
HI1
LO
T Y P I C A L A P P L I C A T I O N
Analog Mixed Signal Group
®
Microsemi
PanelMatch™ StayLit™
5V Dual 6W CCFL Programmable Inverter Module
other voltage source, a digital pot or 500k manual pot. The
inverter contains an internal 215k pull-up to 3V to bias the
pot.
controller may also be used as shown in Figure 1A.
to TTL logic signal to the
lamps. Connect V
(wire with thinner insulation). Never connect V
ground as this will defeat lamp current regulation.
current. Generally the best lamp lifetime correlates with
driving the CCFL at the manufactures nominal current
setting.
intentionally left open.
driven, using an open collector, or open drain logic signal.
This will allow dynamic adjustment of the lamp current for
situations where greater dim range is required, as an
example in nighttime situations. In conjunction with a light
sensor or other timer the panel could be set to higher
brightness
illumination and lower brightness (minimum or typical
output current) at nighttime. Since the dimming ratio is a
factor of both the burst duty cycle and the peak output
current, by using this technique the effective dim ratio can
be increased greater than what the burst duty cycle alone
could provide. Conversely, the SET input could be used to
overdrive the lamp current.
degradation of lamp life from such practices is the user’s
responsibility since not all lamps are designed to be under
or overdriven.
low will toggle high to indicate that an output fault
condition has occurred as summarized in the table to the left
figure 2. FAULT will toggle high if one or both lamps are
open or short circuited. If only one lamp opens, or its high
side shorts to ground then the other lamp should continue to
operate with the FAULT signal going high.
open and/or both lamps are shorted the FAULT will toggle
high if it is not already high and the inverter output will
shutdown. Also if either low side connection of the lamps
is shorted to ground, or the lamps are shorted high side to
low side, FAULT will go high and the inverter will
shutdown. In order to restart the inverter after a fault it is
necessary to toggle the
supply. In fault induced shutdown mode the inverter will
draw about 15mA from V
The brightness control may be a voltage output DAC or
If you need to turn the inverter ON/OFF remotely, connect
Connect V
Use the SET input to program the desired maximum output
Typically the SET pin is permanently wired to ground or
Input connector (CN1-8) FAULT signal which is normally
A 3.3V Logic Level PWM signal from a micro-
P
RODUCTION
HI1
(maximum
and V
LO
HI2
to the low voltage wire lamp return
SLEEP
IN
D
SLEEP
However it can also be actively
output
to high voltage wires from the
ATASHEET
supply.
input or cycle the V
Of course, any possible
input.
LXMG1626-05-45
current)
for
If both lamps
LO
to circuit
daytime
IN
input
Page 5

Related parts for LXMG1626-05-45