Page 1
... MODEL VHB200W-Q24-S3R3 VHB200W-Q24-S5 VHB200W-Q24-S12 VHB200W-Q24-S15 VHB200W-Q24-S24 VHB200W-Q24-S28 VHB200W-Q24-S48 VHB200W-Q48-S3R3 VHB200W-Q48-S5 VHB200W-Q48-S12 VHB200W-Q48-S15 VHB200W-Q48-S24 VHB200W-Q48-S28 VHB200W-Q48-S48 notes: 1. see output derating (page 4) 2. input currents are measured at hominal input voltage 3. efficiency is measured at nominal line, full load INPUT parameter conditions/description ...
Page 2
... PART NUMBER: VHB200W OUTPUT parameter conditions/description voltage accuracy 48V transient response 25% step load change external trim adj. range ripple & noise (20MHz BW) 3 temperature coefficient short circuit protection continuous 5 line regulation 6 load regulation over voltage protection trip range nom. 48V over current protection ...
Page 3
... PART NUMBER: VHB200W MECHANICAL DRAWING th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: half-brick dc-dc converter phone phone 503.612.2300 fax fax 503.612.2382 page date 07/2009 ...
Page 4
... Power Dissipated vs Ambient Temperature and Air Flo w Ambient Temperature ,Ta(Deg. C) FIGURE 1. OUTPUT DERATING (FORCED CONVECTION WITH NO HEAT SINK) Example: What is the minimum airflow necessary for a VHB200W-Q48-S12 operating at nominal line, an output current of 16.7 A, and a maximum ambient temperature of 40°C? Solution: Given: Vin=48 V dc, Vo=12 V dc, Io=16.7 A Determine Power dissipation (Pd): Pd=Pi-Po=Po(1-η ...
Page 5
... Ipeak = 150%*Pout/(η η *Vmin). In the previous example of VHB200W-Q24-S5, the peak input current at 10V was calculated to be 34. fuse may be suit- able for this application. Make sure the fuse voltage rating is higher than the maximum input voltage. ...
Page 6
... R load R trim-down FIGURE 5: TRIM-UP VOLTAGE SETUP The value 100 is the Where: R o,nom nominal output voltage and C values are defined in Table 1. For example, to trim- down the 24V module (VHB200W-Q24-S24 25.92V, R Output A B Voltage( 12, 5.11 511 15, 24, 28V 48V 20 2000 phone phone 503 ...
Page 7
... PART NUMBER: VHB200W 8. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether. is not over 110°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading, the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown ...
Page 8
... INPUT FILTERING AND EMI INTERFERENCE The VHB200W converters have input capacitors that control input current ripple and the associated EMI interference. However, it has not been tested to a formal standard for conducted emissions. Additional filtering may be needed to ensure compliance to an EMI standard ...
Page 9
... VHB200W-Q24-S48 Class A 100uF/100V KY 100uF/100V KY 100uF/100V KY VHB200W-Q24-S48 Class B 82uF/100V KY VHB200W-Q48-S5 Class B 82uF/100V KY VHB200W-Q48-S12 Class B 120uF/100V KY 120uF/100V KY 4.7uF/100V X7R 2220 1000pF/2KV 680pF/2KV VHB200W-Q48-S24 Class B 120uF/100V KY 120uF/100V KY 4.7uF/100V X7R 2220 1500pF/2KV 680pF/2KV VHB200W-Q48-S28 Class A 150uF/100V KY 150uF/100V KY NC VHB200W-Q48-S28 Class B 120uF/100V KY 120uF/100V KY 470uF/100V KY VHB200W-Q48-S48 Class A 100uF/100V KY 100uF/100V KY 100uF/100V KY ...
Page 10
... PART NUMBER: VHB200W 16. OUTPUT FILTERING The converter has built-in capacitors at the output to control ripple and noise. If desired, additional output capacitance can be introduced at the input to the powered equipment. Recommended starting point: one 10μF tantalum and one 1μF ceramic capacitor in parallel at the output. ...