LW015C91 Lineage Power, LW015C91 Datasheet - Page 2

no-image

LW015C91

Manufacturer Part Number
LW015C91
Description
CONVERTER DC/DC 15V 15W OUT
Manufacturer
Lineage Power
Series
LW015r
Type
Isolated with UVLOr
Datasheet

Specifications of LW015C91

Output
15V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
6-DIP Module
1st Output
15 VDC @ 1A
Size / Dimension
2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 105°C
Efficiency
78%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LW015C91
Manufacturer:
Lucent
Quantity:
28
Part Number:
LW015C91
Quantity:
334
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
* Maximum case temperature varies based on power dissipation. See derating curves, Figures 43—45, for details.
Electrical Specifications
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Input Voltage:
Operating Case Temperature
Storage Temperature
I/O Isolation
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current
Input Ripple Rejection (100 Hz—120 Hz)
(See Derating Curves, Figures 43—45.)
(V
1—4.)
(5 Hz to 20 MHz; 12 µH source imped-
ance; T
Continuous
Transient (100 ms)
I
= 0 to V
A
= 25 °C; see Figure 33.)
I, max
Parameter
Parameter
; I
O
= I
O, max
; see Figures
Device
Device
LW
LW
LW
LW
LC
LC
LC
All
All
All
All
All
All
Symbol
Symbol
V
I
I
I, trans
T
I, max
I, max
T
V
V
I
V
V
stg
2
I
C
I
t
I
I
I
I
Min
Min
–40
–55
18
36
0
0
0
Typ
Typ
24
48
45
5
1500
105*
Max
Max
100
125
800
1.6
0.2
50
80
36
75
March 27, 2008
Lineage Power
mAp-p
Unit
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
A
mA
dB
°C
°C
V
A
2
s

Related parts for LW015C91