VPOL16A-12-SIP CUI Inc, VPOL16A-12-SIP Datasheet - Page 6

CONVERTR DC/DC .75/5VOUT 16A SIP

VPOL16A-12-SIP

Manufacturer Part Number
VPOL16A-12-SIP
Description
CONVERTR DC/DC .75/5VOUT 16A SIP
Manufacturer
CUI Inc
Series
V-Infinity VPOL16Ar
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of VPOL16A-12-SIP

Output
0.75 ~ 5V
Number Of Outputs
1
Power (watts)
80W
Mounting Type
Through Hole
Voltage - Input
9 ~ 14V
Package / Case
11-SIP Module (10 Leads)
1st Output
0.75 ~ 5 VDC @ 16A
Size / Dimension
2.00" L x 0.33" W x 0.51" H (50.8mm x 8.4mm x 13mm)
Power (watts) - Rated
80W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
cUL, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Other names
102-1293
PART NUMBER: VPOL16A-12-SIP
7.2 Convection Requirements for Cooling
To predict the ap proximate cooling needed for the module, refer to the
Power De-rating curves in Figures 8 & 9 . These de-rating curves are
approximations of the ambient temperatures and airflows required to
keep the power module temperature below its maximum rating. Once
the module is assembled in the actual system, the module’s
temperature should be checked as shown in Figure 6 to ensure it does
not exceed 120°C.
Proper cooling can be verified by measuring the power module’s
temperature at Q1-pin 6 as shown in Figure 7.
Figure 7. Temperature Measurement Location for VPOL16A-
Tunnel
Bakelite
W ind
20050 SW 112
Note : Dimensions are in millimeters and (inches)
Figure 6. Thermal Test Setup
th
25.4(1.0)
Ave. Tualatin, Oregon 97062
12.7(0.5)
Air
flow
12-SIP
76.2(3.0)
Power Module
ambient temperature
and airflow
Thermocuple Location
for measuring
phone
phone 503.612.2300 fax
DESCRIPTION: point of load converter
7.3 Thermal Considerations
The power module operates in a variety of thermal environments;
however, sufficient cooling should be provided to help ensure reliable
operation of the unit. Heat is removed by conduction, convection, and
radiation to the surrounding environment. The thermal data presented is
based on measurements taken in a set-up as shown in Figure 6.
Figures 8 & 9 represent the test data. Note that the airflow is parallel to
the long axis of the module as shown in Fig 6 for the VPOL16A-12-SIP.
The temperature at either location should not exceed 120 °C. The
output power of the module should not exceed the rated power for the
module (VO, set x IO, max). The VPOL16A-12-SIP thermal data
presented is based on measurements taken in a wind tunnel. The test
setup shown in Figure 7 and EUT need to solder on 33mm x
40.38mm(1.300'' x 1.59'') test pcb. Note that airflow is parallel to the
long axis of the module as shown in Fig 6.
fax 503.612.2382
rev.
page
date
01/2008
6 of 12