OKL-T/3-W5N-C Murata Power Solutions Inc, OKL-T/3-W5N-C Datasheet - Page 14

CONV DC/DC 9.9W 3A 5VIN SMD

OKL-T/3-W5N-C

Manufacturer Part Number
OKL-T/3-W5N-C
Description
CONV DC/DC 9.9W 3A 5VIN SMD
Manufacturer
Murata Power Solutions Inc
Series
Okami™ OKL-T/3-W5r
Type
Point of Load (POL) Non-Isolatedr
Datasheets

Specifications of OKL-T/3-W5N-C

Number Of Outputs
1
Output
0.6 ~ 3.63V
Power (watts)
9.9W
Mounting Type
Surface Mount
Voltage - Input
2.4 ~ 5.5V
Package / Case
12-SMD Module
1st Output
0.6 ~ 3.63 VDC @ 3A
Size / Dimension
0.48" L x 0.48" W x 0.24" H (12.2mm x 12.2mm x 6.1mm)
Power (watts) - Rated
9.9W
Operating Temperature
-40°C ~ 85°C
Efficiency
95.3%
Approvals
CSA, cUL, EN, IEC, UL
Output Power
9.9 W
Input Voltage Range
2.4 V to 5.5 V
Input Voltage (nominal)
5 V
Package / Case Size
12.2 mm x 12.2 mm x6.2 mm
Output Voltage
0.6 V to 3.63 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2212-2
Output Voltage Adustment
The output voltage may be adjusted over a limited range by connecting an
external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim
resistor must be a 1/10 Watt precision metal fi lm type, ±0.5% accuracy or
better with low temperature coeffi cient, ±100 ppm/oC. or better. Mount the
resistor close to the converter with very short leads or use a surface mount
trim resistor.
specifi ed limits of the output voltage or the converter’s maximum power
rating when applying these resistors. Also, avoid high noise at the Trim
input. However, to prevent instability, you should never connect any capaci-
tors to Trim.
OKL-T/3-W5
Resistor Trim Equation, OKL-T/3-W5 models:
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs
of power conversion components. Fuses should also be used when there
is the possibility of sustained input voltage reversal which is not current-
limited. For greatest safety, we recommend a fast blow fuse installed in the
ungrounded input supply line.
For safety agency approvals, install the converter in compliance with the
end-user safety standard, i.e. IEC/EN/UL 60950-1.
Output Voltage
3.3 V.
2.5 V.
2.0 V.
1.8 V.
1.5 V.
1.2 V.
1.0 V.
0.6 V.
R
In the tables below, the calculated resistance is given. Do not exceed the
The installer must observe all relevant safety standards and regulations.
TRIM
(k:) = _____________
V
OUT
1.2
– 0.6
TECHNICAL NOTES
Calculated Rtrim (KΩ)
0.44
0.63
0.86
1.0
1.33
2.0
3.0
∞ (open)
www.murata-ps.com
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate
properly until the ramping-up input voltage exceeds and remains at the
Start-Up Threshold Voltage (see Specifi cations). Once operating, convert-
ers will not turn off until the input voltage drops below the Under-Voltage
Shutdown Limit. Subsequent restart will not occur until the input voltage
rises again above the Start-Up Threshold. This built-in hysteresis prevents
any unstable on/off operation at a single input voltage.
Shutdown whose voltage decays as input current is consumed (such as
capacitor inputs), the converter shuts off and then restarts as the external
capacitor recharges. Such situations could oscillate. To prevent this, make
sure the operating input voltage is well above the UV Shutdown voltage AT
ALL TIMES.
Start-Up Time
Assuming that the output current is set at the rated maximum, the Vin to
Vout Start-Up Time (see Specifi cations) is the time interval between the
point when the ramping input voltage crosses the Start-Up Threshold and
the fully loaded regulated output voltage enters and remains within its
specifi ed accuracy band. Actual measured times will vary with input source
impedance, external input capacitance, input voltage slew rate and fi nal
value of the input voltage as it appears at the converter.
its PWM controller at power up, thereby limiting the input inrush current.
assumes that the converter already has its input voltage stabilized above
the Start-Up Threshold before the On command. The interval is measured
from the On command until the output enters and remains within its
specifi ed accuracy band. The specifi cation assumes that the output is fully
loaded at maximum rated current. Similar conditions apply to the On to Vout
regulated specifi cation such as external load capacitance and soft start
circuitry.
Recommended Input Filtering
The user must assure that the input source has low AC impedance to
provide dynamic stability and that the input supply has little or no inductive
content, including long distributed wiring to a remote power supply. The
converter will operate with no additional external capacitance if these
conditions are met.
Users should be aware however of input sources near the Under-Voltage
These converters include a soft start circuit to moderate the duty cycle of
The On/Off Remote Control interval from On command to Vout regulated
Programmable Output 3-Amp iLGA SMT PoLs
28 Mar 2011 MDC_OKL-T/3-W5 Series.A07 Page 14 of 17
OKL-T/3-W5 Series
email: sales@murata-ps.com

Related parts for OKL-T/3-W5N-C