S8T-BUS03 Omron, S8T-BUS03 Datasheet - Page 11

no-image

S8T-BUS03

Manufacturer Part Number
S8T-BUS03
Description
CONNECTOR DC LINE BUS
Manufacturer
Omron
Series
S8TSr
Datasheet

Specifications of S8T-BUS03

Accessory Type
Bus Line Connectors
For Use With/related Products
S8TS Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S8TBUS03
Engineering Data
■ Derating Curve
Note: 1. “(+1)” indicates redundant operation.
S8T-DCBU-01
S8T-DCBU-01
1
1 (+1)
2
2 (+1)
3
3 (+1)
4
4 (+1)
Number of S8TS-06024@ units
200
192
168
150
100
50
40
36
35
30
25
20
15
10
0
5
0
−20 −10
−20 −10
2. If there is derating problem, use forced air cooling.
3. The ambient temperature is specified at a location 50 mm downward from the main body of the DC Backup Block.
4. The ambient operating temperature range of the battery is 0 to 40°C; it is different from that of S8T-DCBU-01.
5. The amount of output wattage at multi-connected S8TS-06024@ become smaller than the simple sum of each wattage, since S8T-DCBU-
And the ambient temperature of battery is specified with the temperature at the battery surface.
01 consumes energy from S8TS-06024@.
0
0
10
10
Ambient temperature (°C)
Ambient temperature (°C)
20
20
30
30
*9
*3
40
40
200 to 240 VAC
100 to 120 VAC
100 to 120 VAC/200 to 240 VAC
*1
*8
*2
50
50
S8TS-06024@ rated input
60
60
S8T-DCBU-01
88.8
76.8
100
80
60
40
20
0
−20 −10
0
10
Ambient temperature (°C)
*1
*2
*3
*4
*5
*6
*7
*8
*9
20
30
Derating curve
*5
40
*4
50
60
S8T-DCBU-01
146.4
128.4
160
140
120
100
80
60
40
20
0
−20 −10
36 W
30 W
88.8 W
76.8 W
146.4 W
128.4 W
192 W
168 W
0
S8T-DCBU-01
Rated output power
10
Ambient temperature (°C)
20
30
*7
40
*6
50
60
11

Related parts for S8T-BUS03