GP485A TDK Corporation, GP485A Datasheet - Page 39

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
2.4 EMC
208 V input models
1. ESD
2. Fast transients
3. Surge immunity
4. Conducted immunity
5. Radiated immunity
6. Power frequency magnetic field
7. Conducted emission
8. Radiated emission
400 V input models
1. ESD
2. Fast transients
3. Surge immunity
4. Conducted immunity
5. Radiated immunity
6. Power frequency magnetic field
7. Voltage dips, short interruptions
8. Conducted emission
9. Radiated emission
2.5 Safety
1. Applicable Standards
2. Insulation Resistance
2.6 Mechanical Construction
1. Cooling
2. Dimensions (WxHxD)
3. Weight
4. Types of connectors
5. Mounting method
6. Output ground connection
2.7 Reliability Specs
1. Warranty
and voltage variations immunity tests
(400 V AC only)
CE Mark
EN61000-4-2 (IEC 801-2) air-disch. ±8 kV, contact disch. ±4 kV
EN61000-4-4 (IEC 1000-4-3)
EN61000-4-5 (IEC 1000-4-5)
EN61000-4-6 (IEC 1000-4-6)
EN61000-4-3 (IEC 1000-4-3)
EN61000-4-8
EN55011A, FCC part 15J-A
EN55011A, FCC part 15J-A
CE Mark
EN61000-4-2 (IEC 801-2) Air-disch. ±8 kV, contact disch. ±4 kV
EN61000-4-4 (IEC 1000-4-3)
EN61000-4-5 (IEC 1000-4-5)
EN61000-4-6 (IEC 1000-4-6)
EN61000-4-3 (IEC 1000-4-3)
EN61000-4-8
IEC 61000-4-11
EN55011A, FCC part 15J-A
EN55011A, FCC part 15J-A
UL/CUL 60950-1, EN60950-1 recognized. All outputs are hazardous.
(Units with IEMD or ISOL option are recognized up to 400 V output).
CE Mark 208 & 400 V AC inputs only (CB scheme).
100 MΩ at 500 V DC
Fan driven, airflow from front to rear. Supplemental vents on side that shall not
be blocked. EIA rack mounting, stackable. “Zero stackable” top and bottom.
Slides or suitable rear support required.
W:19” rack, H: 3 U – 5.22” (133 mm), D: 22.2” (564 mm)
without connectors.
43 kg / 97 lbs
1. Input: Threaded studs and terminal cover. Stain relief optional.
2. Output: Up to and including 300 V models: bus-bars.
Greater than 300 V models: threaded stud terminals.
3. Analog programming: DB25, plastic connector, AMP, 747461-5, female on
power supply, male on mating connector 747321. Standard 25 pin D connector.
Standard 19” rack mount, provision for standard slides.
Slide/rear support is required; do not mount by F/P only.
M5 Stud
5 years
39