GP485A TDK Corporation, GP485A Datasheet - Page 48

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications ZUP Series
*1, *2, *3, *4, *5, *6, *8, *11, *12: annotation on page 52.
48
Model
Output voltage (*1)
Output current (*2)
Rated output power
Constant voltage
Constant current
Programming (*9)
Overvoltage
Protection (*10)
Hold-up time
Display
Output protections
Input
Environment
Mechanical
Load regulation
Line regulation
RMS ripple (5 Hz –1 MHz Bandwidth)
Ripple (pk to pk) (20 MHz Bandwidth)
Recovery time (*3)
Temperature coefficient
Temperature drift
UP Programming response time (*4)
Down programming
Response time
Load regulation (*5)
Line regulation (*6)
RMS ripple (5 Hz–1 MHz Bandwidth)
Temperature coefficient
Temperature drift (*8)
Voltage
Current
Voltage
Current
Status
Shock
Weight
Size (WxHxD)
Input voltage (*11)
Input current (*12 )
Inrush current (100/200 V)
Efficiency (*12)
Input current harmonics
Power factor (TYP)
Operating temperature
Operating humidity
Storage temperature
Operating humidity
Vibration
Resolution
Accuracy
Resolution
Accuracy
Full load
No load
V
A
W
mV
mV
ms
ms
ms
ms
mA
V
A
A
%
kg
mm
ZUP6-33
0-6
0-33
198
0.005 %+2 mV, from No load to Full load, constant input voltage
0.005 %+1 mV, from 85-132 V AC or 170-265 V AC, constant load
5
50
1
30 ppm/°C from rated voltage following
30-minute warm-up.
0.01 %+2 mV Change in output, over 8-hour interval
under constant line, load and ambient temperature
following 30-minute warm-up
50
50
250
0.01 %+5 mA
0.01 %+2 mA
50
100 ppm/ °C from rated current
following 30-minute warm-up.
0.02 %+5 mA
Better than 0.028 % of rated output voltage
0.02 %+5 mV
Better than 0.03 % of rated output current
0.4 %+40 mA
0–7.5
20 ms @ 100 V/200 V AC, rated output voltage and output current.
3 digits (6 V; 20 V; 36 V; 60 V; 80 V);
3.5 digits (10 V; 120 V) accuracy: 0.2 % ±2 digits
3.5 digits (132 A); All others 3 digits, accuracy: 0.5 % ±3 digits
CV/CC, Alarm, Fold, Local/Remote, On/Off
Over Voltage, Over Temperature, Foldback.
85–265 V AC Continuous, 47–63 Hz
3.0/1.5
15/30 (*7)
69/72
Complies with EN61000-3-2, Class A
0.99 at 100/200 V AC, 100 % load.
0 to 50 °C ; 100 % Load
30 – 90 % RH (No dewdrop).
–20 to 70 °C
10 – 95 % RH (No dewdrop).
10 – 55 Hz, Amplitude (sweep 1 min) 2 g, X, Y, Z,
When mounted with mounting screws.
Less than 20 g
2.9
200 W and 400 W units: 70 x 124 x 350.
800 W units: 140 X 124 X 350 (Refer to outline drawing)
ZUP6-66
0-6
0-66
396
5
50
1
50
50
350
0.01 %+5 mA
0.01 %+2 mA
100
0.02 %+5 mA
0.02 %+5 mV
0–7.5
3.2
5.6/2.7
15
74/77
ZUP6-132
0-6
0-132
792
8
100
1
60
50
0.07 %+10 mA
0.01 %+5 mA
200
0.05 %+10 mA
0.02 %+5 mV
0–7.5
11.2/5.4
30
74/77
5.8