EZ801900100ZAC Zilog, EZ801900100ZAC Datasheet
EZ801900100ZAC
Specifications of EZ801900100ZAC
EZ801900100ZAC
Related parts for EZ801900100ZAC
EZ801900100ZAC Summary of contents
Page 1
... Table 1 lists the PC requirements for running ZDS II. Table 1. ZDS II System Requirements Recommended Configuration PC running MS Windows XP, SP1 Pentium III/500 MHz processor 128 MB RAM ZiLOG Worldwide Headquarters • 532 Race Street • San Jose, CA 95126 Telephone: 408.558.8500 • Fax: 408.558.8300 • ® Development Platform zilog.com ® ...
Page 2
... Microsoft support page for assistance: http://support.microsoft.com/default.aspx?scid=KB;en-us;q155217 2. ZiLOG recommends registering your new ZDS II software. Registering ZDS II is quick and easy! Please see the enter the requested information. Certain software components from ZiLOG can only be obtained upon online Note: registration ...
Page 3
... JP1/JP2 on the eZ80190 Module to pin 1 of JP1/JP2 on the eZ80 Development Platform. Note: The eZ80190 Module features two 60-pin connectors. Ensure that the RJ45 connector on the module is hanging over the edge of the eZ80 QS000413-0606 ZiLOG website for the latest version. ® Development Platform and the Hub 5 VDC ...
Page 4
Development Kit Quick Start Guide Page 4 Platform, and that module jumpers JP1 and JP2 are aligned with their recepta- cles on the platform. JP1/JP2 pin 60 on the module fits into pin 50 of the receptacle on the ...
Page 5
PC. The subnet portion of the IP address, 192.168.1, should be the same on the ZPAK II unit and the PC. The host portion of the IP address (the fourth octet), should be different (50 and 21). ...
Page 6
Development Kit Quick Start Guide Page the panel labeled LAN or High-Speed Internet, double-click the Local Area Connection icon. The Local Area Connection Status dialog box appears, as shown in Figure 4. Figure 4. The Local ...
Page 7
In the Local Area Connection Status dialog box, click the Properties button. The Local Area Connection Properties dialog box appears, as shown in Figure 5. Figure 5. The Local Area Connection Properties Dialog QS000413-0606 eZ80190 Development Kit Quick Start ...
Page 8
Development Kit Quick Start Guide Page the panel labeled This connection uses the following items:, select the Internet Protocol (TCP/IP) item to highlight it, and click the Properties button (see Figure 5 for an example). The ...
Page 9
... The serial port of the PC should already be connected to the console serial port of the ZPAK II unit. 2. Launch HyperTerminal on the PC by navigating from the Start menu to Programs → Accessories → HyperTerminal or Accessories → Communications → Hyper- Terminal, depending upon your Windows OS. 3. Create a new connection in HyperTerminal by selecting the appropriate COM port in the Connect using: field of the Connect To dialog ...
Page 10
... Pool 1524 32 created buffer Pool 4096 8 IP Address: 192.168.1.50 IP Subnet: 192.168.1.0/255.255.255.0 IP Gateway: 192.168.1.254 netstart exiting, stack extent 379/2048 ZPAKII version x.x Copyright © 2001-2002 ZiLOG, Inc. All Rights Reserved. ZPAKII Console version 1.5 Type 'H' for help ZPAKII:> Note: In the example output above, stack software, and prompt is not case-sensitive ...
Page 11
... Using ZDS II, the user downloads the steps below to build and run the demo. 1. Launch ZDS II by navigating from the Start menu to Programs → ZiLOG ZDS II– eZ80_<Version> → ZDS II–eZ80_<version>. From the File menu in ZDS II, choose Open Project, and navigate to the following ...
Page 12
... When the demo software is running, the dot-matrix LED display on the eZ80 opment Platform should be illuminated and stepping through a number of display pat- terns. Please refer to the ZiLOG Developer Studio–eZ80 User Manual (UM0123) for details regarding the development of eZ80 user manual contained in this kit to review hardware operation in detail. ...
Page 13
... ZiLOG will post future software updates on zilog.com for registered customers nonregistered customer, you can still browse the software on zilog.com, but you will not be able to download certain software components. Related Documents The documents listed in Table 3 apply to the eZ80190 microprocessor. ...
Page 14
... Fax: 408.558.8300 www.ZiLOG.com Document Disclaimer ZiLOG is a registered trademark of ZiLOG Inc. in the United States and in other countries. All other products and/or service names mentioned herein may be trademarks of the companies with which they are associated. ©2006 by ZiLOG, Inc. All rights reserved. Information in this publication concerning the devices, applications, or technology described is intended to suggest possible uses and may be superseded ...